Protocol Gateways

  • You've just added this product to the cart:

    PLX31-MBTCP-PND

    PLX31-MBTCP-PND
    PLX31-MBTCP-PND

    PLX31-MBTCP-PND

    The Modbus TCP/IP to PROFINET device gateway offers bi-directional data transfer between a PROFINET Controller and Modbus TCP/IP networks. The Modbus TCP/IP driver uses multiple clients and servers for faster data throughput. The PROFINET driver operates as a PROFINET device (slave).

    The PLX31-MBTCP-PND gateways are stand-alone DIN-rail mounted units that provide one Ethernet port for communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.

  • You've just added this product to the cart:

    PLX31-MBTCP-SIE

    PLX31-MBTCP-SIE
    PLX31-MBTCP-SIE

    PLX31-MBTCP-SIE

    ProSoft Technology’s EtherNet/IP to Modbus® TCP/IP communication gateway allows high-speed bi-directional data transfers between Rockwell Automation® PACs and Schneider Electric® PACs. Our Modbus TCP/IP driver features multiple client and server functionality, for faster data transmission. Two separate Ethernet ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address. In addition, the gateway includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.

  • You've just added this product to the cart:

    PLX31-PND-MBS

    PLX31-PND-MBS
    PLX31-PND-MBS

    PLX31-PND-MBS

    The PROFINET device to Modbus Serial gateway offers bi-directional data transfers between a PROFINET Controller and Modbus serial (RTU and ASCII) devices. The serial port can be configured as either a Modbus master or slave. The PROFINET interface operates as a PROFINET device (slave).

    The PLX31-PND-MBS gateway is a stand-alone DIN-rail mounted unit that provides Ethernet connectivity for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.

  • You've just added this product to the cart:

    PLX31-PND-MBS4

    PLX31-PND-MBS4
    PLX31-PND-MBS4

    PLX31-PND-MBS4

    The PROFINET device to Modbus Serial gateway offers bi-directional data transfers between a PROFINET Controller and Modbus serial (RTU and ASCII) devices. Each Modbus serial port can be configured as either a Modbus master or slave. The PROFINET interface operates as a PROFINET device (slave).

    The PLX31-PND-MBS4 gateway is a stand-alone DIN-rail mounted unit that provides Ethernet connectivity for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.

  • You've just added this product to the cart:

    PLX32-EIP-MBTCP

    PLX32-EIP-MBTCP
    PLX32-EIP-MBTCP

    PLX32-EIP-MBTCP

    ProSoft Technology’s EtherNet/IP to Modbus® TCP/IP communication gateway allows high-speed bi-directional data transfers between Rockwell Automation® PACs and Schneider Electric® PACs. Our Modbus TCP/IP driver features multiple client and server functionality, for faster data transmission. Two separate Ethernet ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address. In addition, the gateway includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.

  • You've just added this product to the cart:

    PLX32-EIP-PND

    PLX32-EIP-PND
    PLX32-EIP-PND

    PLX32-EIP-PND

    The EtherNet/IP to PROFINET device gateway offers bi-directional data transfers between a PROFINET Controller and EtherNet/IP networks. The PLX32-EIP-PND gateway is a stand-alone DIN-rail mounted unit that provides two Ethernet ports, with each port using a different subnet.

    The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup. The EtherNet/IP Driver uses Class 1 I/O connections or Class 3 Message instructions. The PROFINET driver operates as a PROFINET Class A device.

  • You've just added this product to the cart:

    PLX32-EIP-SIE

    PLX32-EIP-SIE
    PLX32-EIP-SIE

    PLX32-EIP-SIE

    ProSoft Technology’s EtherNet/IP to Siemens Industrial Ethernet communication gateway allows high-speed bi-directional data transfers between Rockwell Automation® PACs and Siemens® S7 PACs. Two separate Ethernet ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address.

    In addition, the gateway includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.

  • You've just added this product to the cart:

    PLX32-MBTCP-PND

    PLX32-MBTCP-PND
    PLX32-MBTCP-PND

    PLX32-MBTCP-PND

    The Modbus TCP/IP to PROFINET device gateway offers bi-directional data transfer between a PROFINET Controller and Modbus TCP/IP networks. The Modbus TCP/IP driver uses multiple clients and servers for faster data throughput. The PROFINET driver operates as a PROFINET device (slave).

    The PLX32-MBTCP-PND gateways are stand-alone DIN-rail mounted units that provide two Ethernet ports for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.

  • You've just added this product to the cart:

    PLX32-MBTCP-SIE

    PLX32-EIP-MBTCP
    PLX32-EIP-MBTCP

    PLX32-MBTCP-SIE

    ProSoft Technology’s Modbus® TCP/IP to Siemens Industrial Ethernet gateway allows high speed bi-directional data transfers between Schneider Electric® PACs and Siemens S7 and S5 PACs.

    Two ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address.

  • You've just added this product to the cart:

    PLX81-EIP-61850

    PLX81-EIP-61850
    PLX81-EIP-61850

    PLX81-EIP-61850

    ProSoft Technology’s EtherNet/IP to IEC 61850 gateway enables communication between the Intelligent Electronic Devices (IEDs) on an IEC- 61850 network and Programmable Automation Controllers (PACs) on an EtherNet/IP network.

    The module operates as an EtherNet/IP server, supporting both Class 1 and Class 3 EtherNet/IP services. Primary data transfer is performed through a Class 1 server connection supporting up to 10 Implicit I/O connections. Additionally the module can also communicate with up to 2 other EtherNet/IP Clients using Class 3 messaging services.

  • You've just added this product to the cart:

    PLX81-MNET-61850

    PLX81-MNET-61850
    PLX81-MNET-61850

    PLX81-MNET-61850

    The Modbus TCP/IP to IEC 61850 gateway enables communication between the Intelligent Electronic Devices (IEDs) on an IEC 61850 network and Programmable Logic Controllers (PLCs) or Programmable Automation Controllers (PACs) on a Modbus TCP/IP network.

    The configuration utility software provided with the gateway uses IED configuration files to import complex IEC 61850 data structures. The utility creates Variable files and Function Block files for import into Unity Pro projects for Quantum or M340 processors.

    IEC 61850 is the international standard that defines the hardware and communication requirements for all devices within substation automation. The standardized naming conventions imposed by the IEC 61850 standard improves interoperability between systems provided by diverse manufactures or created by multiple system integrators.

  • You've just added this product to the cart:

    PLX82-EIP-61850

    PLX82-EIP-61850
    PLX82-EIP-61850

    PLX82-EIP-61850

    The ProSoft Technology®EtherNet/IP to IEC 61850 communication gateway allows Rockwell Automation® PACs to interface with IEC 61850 Intelligent Electronic Devices (IED) such as substation power monitors and relays. The gateway acts as an IEC 61850 Client polling the devices on your network.

    The two ports allow the IEC 61850 and EtherNet/IP™ protocols to reside on separate subnets.