PROFIBUS DPV1 Master for CompactLogix

ILX69-PBM

The ILX69-PBM PROFIBUS DPV1 Master module provides all the advantages of in-chassis PROFIBUS communication, such as the inclusion of an AOI and the Autoscan features which greatly reduce your commissioning time, and ComDTM that provides remote Ethernet connectivity with asset management software.

With these modules, CompactLogix™ processors can easily communicate with slave devices supporting PROFIBUS DPV0 and DPV1 protocol. The module acts as an input/output module between the PROFIBUS network and the processor supporting complete Master specifications according to IEC 61158.

Description

PROFIBUS DPV1 Master for CompactLogix

The ILX69-PBM PROFIBUS DPV1 Master module provides all the advantages of in-chassis PROFIBUS communication, such as the inclusion of an AOI and the Autoscan features which greatly reduce your commissioning time, and ComDTM that provides remote Ethernet connectivity with asset management software.

With these modules, CompactLogix™ processors can easily communicate with slave devices supporting PROFIBUS DPV0 and DPV1 protocol. The module acts as an input/output module between the PROFIBUS network and the processor supporting complete Master specifications according to IEC 61158.

Features and Benefits

  • AOI: Module communication is integrated within Studio/RSLogix 5000 using a sample Add-On Instruction (AOI), or sample ladder logic file, reducing commissioning time.
  • Autoscan: The new Autoscan feature reduces start up times and simplifies troubleshooting by scanning the PROFIBUS network and uploading slave device addresses and configuration information. (Reads and maps nodes automatically to the module.)
  • ComDTM: Allows remote Ethernet connectivity with Asset Management Software significantly lowering maintenance costs. You can configure, commission, maintain and diagnose your fieldbus devices throughout their entire lifecycle with this comprehensive, fully integrated engineering and maintenance environment.
  • SD card slot (SD card optional) is used for storing configuration files in the event of a disaster. It can also be used to update the firmware of the module without the need of a 1769 CPU.

Architectures

ILX69-PBM-Schematic

Specifications

PROFIBUS DP Specifications

Specification  Description
Slaves Maximum 125
Input/Output Maximum 244 Bytes per Slave
Input Data Maximum 5712 Bytes
Acyclic Data DPV1
Status data 88 Bytes
Output data Maximum 5760 Bytes
DPV1 services Class 1 Read/Write
Class 1 Alarm
Class 2 Initiate/Read/Write/Data transport/Abort
Services Global-Control, Slave-Diagnostic, Set-Parameter
Sync, Freeze Command Supported
Baud rate 9.6 kBaud,
19.2 kBaud,
45.45 kBaud,
93.75 kBaud,
187.5 kBaud,
500 kBaud,
1.5 MBaud,
3 MBaud,
6 MBaud,
12 MBaudAuto-detection mode is supported