Modbus TCP/IP to PROFINET Device Gateway
PLX31-MBTCP-PND
The Modbus TCP/IP to PROFINET device gateway offers bi-directional data transfer between a PROFINET Controller and Modbus TCP/IP networks. The Modbus TCP/IP driver uses multiple clients and servers for faster data throughput. The PROFINET driver operates as a PROFINET device (slave).
The PLX31-MBTCP-PND gateways are stand-alone DIN-rail mounted units that provide one Ethernet port for communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.
- Description
Description
Modbus TCP/IP to PROFINET Device Gateway
The Modbus TCP/IP to PROFINET device gateway offers bi-directional data transfer between a PROFINET Controller and Modbus TCP/IP networks. The Modbus TCP/IP driver uses multiple clients and servers for faster data throughput. The PROFINET driver operates as a PROFINET device (slave).
The PLX31-MBTCP-PND gateways are stand-alone DIN-rail mounted units that provide one Ethernet port for communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.
Architectures
Specifications
Modbus TCP/IP Specifications
Supported Modbus Function Codes | 1: Read Coil Status
2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil 6: Preset (Write) Single Holding Register |
15: Force (Write) Multiple Coils
16: Preset (Write) Multiple Holding Registers 22: Mask Write Holding Register (server only) 23: Read/Write Holding Registers (server only) |
Supported clients | 10 | |
Supported servers | MBAP = 5, Encapsulated = 5 | |
Command List | Up to 160 fully configurable client commands | |
Status Data | Error codes reported individually for each command | |
Command List Polling | Each command can be individually enabled or disabled; write-only-on-data-change is available |
PROFINET Specifications
Specification | Description |
Driver Type | Class A Device |
PROFINET I/O Data | 1440 bytes IN, 1440 bytes OUT |
Exchange Types | Cyclic Real-time (RT) and Acyclic Data |
Hardware Specifications
Specification | Description |
Power Supply | 24 VDC nominal 10 to 36 VDC allowed Positive, Negative, GND Terminals |
Current Load | 24 VDC nominal @ 300 mA
10 to 36 VDC @ 610 mA maximum |
Operating Temperature | -25°C to 70°C (-13°F to 158°F ) |
Storage Temperature | -40°C to 80°C (-40°F to 176°F ) |
Relative Humidity | 5% to 95% RH with no condensation |
Shock | IEC 60068-2-27; 15G @ 11ms, 3-Axis (Operational)
IEC 60068-2-27; 30G @ 18ms, 3-Axis (Non-Operational) |
Vibration | IEC 60068-2-6; 5G @ 10 to 150 Hz |
Dimensions (H x W x D) |
5.38 x 1.99 x 4.38 in 13.67 x 5.05 x 11.13 cm |
LED Indicators | *Configuration (CFG) *Error (ERR) Status *Power (PWR) *Hardware Fault (FLT) *Network Status (NS) Modbus TCP/IP Class I or Class III -Connection Status (Modbus TCP/IP only) |
Ethernet Port | *10/100Mbit RJ45 Connector Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991 *Ethernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration |
Shipped With Each Unit | 2.5 mm screwdriver, J180 Power Connector |