PROFINET Device to Modbus Serial Gateway with four serial ports
PLX31-PND-MBS4
The PROFINET device to Modbus Serial gateway offers bi-directional data transfers between a PROFINET Controller and Modbus serial (RTU and ASCII) devices. Each Modbus serial port can be configured as either a Modbus master or slave. The PROFINET interface operates as a PROFINET device (slave).
The PLX31-PND-MBS4 gateway is a stand-alone DIN-rail mounted unit that provides Ethernet connectivity for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.
- Description
Description
PROFINET Device to Modbus Serial Gateway with four serial ports
The PROFINET device to Modbus Serial gateway offers bi-directional data transfers between a PROFINET Controller and Modbus serial (RTU and ASCII) devices. Each Modbus serial port can be configured as either a Modbus master or slave. The PROFINET interface operates as a PROFINET device (slave).
The PLX31-PND-MBS4 gateway is a stand-alone DIN-rail mounted unit that provides Ethernet connectivity for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.
Architectures
Features and Benefits
- PROFINET v2 certification with PROFINET class A compliance
- Field-proven with thousands of Modbus serial devices, and multiple PROFINET controllers from multiple vendors
- Remotely view and diagnose Modbus and PROFINET networks
- Remote configuration via the free, intuitive, ProSoft Configuration Builder (PCB) software
- Each Modbus serial port supports master or slave mode
Specifications
PROFINET Specifications
Specification | Description |
Driver Type | Class A Device |
PROFINET I/O Data | 1440 bytes IN, 1440 bytes OUT |
Exchange Types | Cyclic Real-time (RT) and Acyclic Data |
Modbus Serial Specifications
Command List | Up to 100 commands per master port, each fully configurable for Function Code, slave address, register to/from addressing and word/bit count. | ||
Supported Modbus Function Codes | 1: Read Coil Status
2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil 6: Preset (Write) Single Holding Register |
15: Force (Write) Multiple Coils
16: Preset (Write) Multiple Holding Registers 22: Mask Write Holding Register (slave only) 23: Read/Write Holding Registers (slave only) |
|
Software configurable communication
parameters |
Baud rate: 110 baud to 115.2 kbps
Parity: None, Even, Odd RTS on/off delay: 0 to 65535 milliseconds Modbus Modes: RTU with CRC-16 or ASCII with LRC error checking Floating Point Data supported, support for Enron and Daniel |
||
Polling of Command List | Configurable polling of command list, including continuous and on change of data | ||
Status Data | Error codes available on an individual command basis. In addition, a slave status list is maintained per serial port | ||
Node Address | 1 to 247 (software selectable) | ||
RS Interface | RS232, RS422, and RS485 |