EtherNet/IP to Modbus TCP/IP Communications Gateway
PLX32-EIP-MBTCP
ProSoft Technology’s EtherNet/IP™ to Modbus® TCP/IP communication gateway allows high-speed bi-directional data transfers between Rockwell Automation® PACs and Schneider Electric® PACs. Our Modbus® TCP/IP driver features multiple client and server functionality, for faster data transmission. Two separate Ethernet ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address. In addition, the gateway includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.
A conformal coating option is available for this product.
- Description
Description
EtherNet/IP to Modbus TCP/IP Communications Gateway
ProSoft Technology’s EtherNet/IP™ to Modbus® TCP/IP communication gateway allows high-speed bi-directional data transfers between Rockwell Automation® PACs and Schneider Electric® PACs. Our Modbus® TCP/IP driver features multiple client and server functionality, for faster data transmission. Two separate Ethernet ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address. In addition, the gateway includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.
A conformal coating option is available for this product.
Architectures
Specifications
EtherNet/IP™ Specifications
Specification | Description |
Number of Class 3 Server Connections | 5 |
Supported PLC Types | PLC2, PLC5, SLC, CLX, CMPLX, MICROLX |
Supported Message Types | PCCC and CIP |
Class 3 Client Connections | Connected: 2 Unconnected: 1 |
Number of Class 1 I/O Connections | 2 |
I/O connection sizes | 248/248 |
Max RPI time | 5 ms per connection |
CIP Services Supported | 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write |
Command List | Support for 100 commands per Client, each configurable for command type, IP address, register to/from addressing and word/bit count. |
Command Sets | PLC-2/PLC-3/PLC5 Basic Command Set PLC5 Binary Command Set PLC5 ASCII Command Set SLC500 Command Set |
Modbus® TCP/IP Specifications
Specification | Description |
Supported Modbus Function Codes | 1: Read Coil Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil 6: Preset (Write) Single Holding Register 15: Force (Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers 22: Mask Write Holding Register (Slave Only) 23: Read/Write Holding Registers (Slave Only) |
Supported Clients | 10 |
Supported Servers | MBAP: 5 Encapsulated: 5 |
Command List | Up to 160 fully configurable Client commands |
Status Data | Error codes reported individually for each command |
Command List Polling | Each command can be individually enabled or disabled; write-only-on-data-change is available |