{"id":1656,"date":"2017-12-16T10:01:19","date_gmt":"2017-12-16T10:01:19","guid":{"rendered":"http:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=1656"},"modified":"2021-06-24T18:22:32","modified_gmt":"2021-06-24T18:22:32","slug":"mvi56e-mcm-mcmxt","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/mvi56e-mcm-mcmxt\/","title":{"rendered":"Modbus Master\/Slave Serial Enhanced Communication Module, eXTreme Temp <br \/><h5>MVI56E-MCM\/MCMXT<\/h5>"},"content":{"rendered":"<div>\n<h2>Modbus Master\/Slave Enhanced Network Interface Module for ControlLogix<\/h2>\n<p>The MVI56E Communication Module allows for Modbus Master and\/or Slave connectivity from Rockwell Automation\u00ae ControlLogix\u00ae processors to Modbus RTU\/ASCII devices. Each MVI56E port can be configured as a Master or Slave.<\/p>\n<p>The MVI56E-MCM and MVI56E-MCMXT act as input\/output modules on the ControlLogix backplane, making Modbus data appear as I\/O data to the processor. Two independently configurable serial ports can operate on the same or different Modbus networks. The MVI56E-MCM is designed for standard process applications and the MVI56E-MCMXT is designed for the Logix-XT\u2122 control platform, allowing it to operate in extreme environments. It can tolerate higher operating temperatures and has a conformal coating to protect it from harsh or caustic conditions.<\/p>\n<\/div>\n<h2>Features and Benefits<\/h2>\n<table class=\"renderedtable\" width=\"100%\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"150\">Backward Compatibility<\/td>\n<td valign=\"top\" width=\"550\">\n<ul>\n<li>All MVI56E products are backward-compatible with earlier MVI56 modules allowing direct replacement without the need to change existing controller programs<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"150\">10,000 Word Database<\/td>\n<td valign=\"top\" width=\"550\">\n<ul>\n<li>Allows you to gather more data from your devices, which improves operational performance<\/li>\n<li>Enjoy Enhanced features and flexibility without incurring expensive reprogramming costs<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"150\">Add-On Instruction<\/td>\n<td valign=\"top\" width=\"550\">\n<ul>\n<li>Module configuration stored within the RSLogix\u2122 5000 project (ACD file)<\/li>\n<li>No additional programming or configuration software is required<\/li>\n<li>Add-On Instruction for RSLogix 5000 version 16 or higher cuts development time and costs<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"150\">CIPconnect\u00ae Enabled<\/td>\n<td valign=\"top\" width=\"550\">\n<ul>\n<li>Facilitates remote user access across the ControlLogix backplane through Rockwell Automation\u2019s 1756-ENBT module<\/li>\n<li>Configure, diagnose, and analyze process data and communications status<\/li>\n<li>Bridge through multiple ENBT\/CNBT links to connect to MVI56E-MCMs installed in remote chassis for configuration and diagnostics<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"150\">Add-On Profile<\/td>\n<td valign=\"top\" width=\"550\">\n<ul>\n<li>Simplifies adding the module in an RSLogix 5000 project<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Specifications<\/h2>\n<ul>\n<li>Backward-compatible with previous MVI56-MCM version<\/li>\n<li>Single Slot &#8211; 1756 ControlLogix\u00ae backplane compatible<\/li>\n<li>10\/100 MB Ethernet port for network configuration and diagnostics with Auto Cable Crossover Detection<\/li>\n<li>User-definable module data memory mapping of up to 10,000 16-bit registers<\/li>\n<li>4-character, scrolling, alphanumeric LED display of status and diagnostic data in plain English<\/li>\n<li>ProSoft Discovery Service (PDS) software finds the module on the network and assigns a temporary IP address to facilitate module access<\/li>\n<li>Supports RIUP (Remove and Insert Under Power)<\/li>\n<\/ul>\n<h2>Functional Specifications<\/h2>\n<p>The MVI56E-MCM will operate on a Local or Remote rack (For remote rack applications with smaller data packet size please refer to the MVI56E-MCMR product)<\/p>\n<ul>\n<li>Supports Enron version of Modbus protocol for floating-point data transactions<\/li>\n<li>PCB includes a powerful Modbus network analyzer<\/li>\n<li>Special functions (command control, event commands, status, and so on) are supported by message transfer (unscheduled) using the MSG instruction<\/li>\n<li>Error codes, network error counters, and port status data available in user data \u00a0memory<\/li>\n<\/ul>\n<h2>Architectures<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-3126\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/Schematic-MVI56E-MCM.png\" alt=\"Schematic MVI56E-MCM\" width=\"1386\" height=\"786\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/Schematic-MVI56E-MCM.png 1386w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/Schematic-MVI56E-MCM-490x278.png 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/Schematic-MVI56E-MCM-500x284.png 500w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/Schematic-MVI56E-MCM-768x436.png 768w\" sizes=\"(max-width: 1386px) 100vw, 1386px\" \/><\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-3127\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/Schematic-MVI56E-MCMXT.png\" alt=\"Schematic MVI56E-MCMXT\" width=\"1386\" height=\"786\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/Schematic-MVI56E-MCMXT.png 1386w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/Schematic-MVI56E-MCMXT-490x278.png 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/Schematic-MVI56E-MCMXT-500x284.png 500w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/Schematic-MVI56E-MCMXT-768x436.png 768w\" sizes=\"(max-width: 1386px) 100vw, 1386px\" \/><\/p>\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:\u00a0 All products are pre-order items<\/p>\n<p style=\"text-align: center;\"><strong>More:<\/strong>\u00a0 <a href=\"https:\/\/www.prosoft-technology.com\/Products\/Rockwell-Automation-In-chassis\/Platform\/ControlLogix\/Modbus-Master-Slave-Enhanced-Network-Interface-Module-for-ControlLogix\">Specifications, downloads &amp; certifications<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The MVI56E-MCM and MVI56E-MCMXT act as input\/output modules on the ControlLogix backplane, making Modbus data appear as I\/O data to the processor. Two independently configurable serial ports can operate on the same or different Modbus networks. The MVI56E-MCM is designed for standard process applications and the MVI56E-MCMXT is designed for the Logix-XT\u2122 control platform, allowing it to operate in extreme environments. It can tolerate higher operating temperatures, and has a conformal coating to protect it from harsh or caustic conditions.<\/p>\n","protected":false},"featured_media":3128,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[583,152,153],"product_tag":[461,460],"class_list":{"0":"post-1656","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-controllogix","7":"product_cat-prosoft-technology","8":"product_cat-rockwell-automation-in-chassis","9":"product_tag-extreme-temp","10":"product_tag-modbus-master-slave-serial-enhanced-communication-module","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/1656","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=1656"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/1656\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/3128"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=1656"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=1656"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=1656"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=1656"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}