{"id":1680,"date":"2017-12-16T12:54:34","date_gmt":"2017-12-16T12:54:34","guid":{"rendered":"http:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=1680"},"modified":"2021-06-22T08:10:20","modified_gmt":"2021-06-22T08:10:20","slug":"mvi56e-mnetcr","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/mvi56e-mnetcr\/","title":{"rendered":"Modbus TCP\/IP Master\/Slave Enhanced Comm. Module in Remote Chassis-Client Only <br ><h5>MVI56E-MNETCR<\/h5>"},"content":{"rendered":"<div>\n<h2>Modbus TCP\/IP Multi-Client Enhanced Network Interface Module with Reduced Data Block for ControlLogix<\/h2>\n<p><b><i>Which of our Modbus TCP\/IP modules is best for your application?<\/i><\/b><\/p>\n<p><a href=\"https:\/\/www.youtube.com\/watch?v=fR70cXH8eOA\" target=\"_blank\" rel=\"noopener\">Watch this Video<\/a><\/p>\n<p>The MVI56E Modbus TCP\/IP Multi-Client Enhanced Communication Module for Remote Chassis allows Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to interface easily with multiple Modbus TCP\/IP server-compatible instruments and devices. The Multi-Client module improves performance when controlling multiple servers on a Modbus TCP\/IP network, by supporting up to 30 clients.<\/p>\n<p>MVI56E enhancements include configuration and management through the module Ethernet port, CIPconnect technology for bridging through ControlNet and EtherNet\/IP networks, and has a web server to access on-board documentation, Add-On Instructions, and sample program files.<br \/>\nThis module uses a small I\/O data image for transfer of data between the module and the ControlLogix processor, making it ideal for ControlNet or Ethernet applications with the module in a remote rack.<\/p>\n<\/div>\n<h2>Features and Benefits<\/h2>\n<table class=\"renderedtable\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td width=\"150\" valign=\"top\">Supports up to 30 Clients<\/td>\n<td width=\"550\" valign=\"top\">\n<ul>\n<li>Faster response for multi-server applications<\/li>\n<li>Reduces network traffic<\/li>\n<li>Minimizes impact to other server communications when one server device goes off-line<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\" valign=\"top\">RSLogix 5000 Integrated<\/td>\n<td width=\"550\" valign=\"top\">\n<ul>\n<li>The module communication is integrated with RSLogix 5000 using a supplied Add-On Instruction (AOI) or ladder file<\/li>\n<li>No additional PAC\/PLC programming required<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\" valign=\"top\">Enable\/Disable commands easily from ladder logic.<\/td>\n<td width=\"550\" valign=\"top\">\n<ul>\n<li>Programatically enable various networked devices and their functions to support multiple applications or recipes, without having to reconfigure the module<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\" valign=\"top\">Remotely configure and diagnose problems<\/td>\n<td width=\"550\" valign=\"top\">\n<ul>\n<li>Easy to use Windows-based configuration software connects through remote racks using EtherNet\/IP and\/or ControlNet via a 1756-EnxT and\/or 1756-CNB interface module without requiring RSLinx OEM saving you money<\/li>\n<li>Allows support of IT and Automation network segmentation<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\" valign=\"top\">Web-enabled Ethernet port<\/td>\n<td width=\"550\" valign=\"top\">\n<ul>\n<li>The module has a built-in web server for easy access to documentation, module status, and to update firmware<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\" valign=\"top\">MVI56 backward compatible<\/td>\n<td width=\"550\" valign=\"top\">\n<ul>\n<li>Assists in extending current MVI56 applications by using newer technology that supports existing MVI56 ladder logic and module configuration<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div id=\"specs\" class=\"tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom\" role=\"tabpanel\" aria-labelledby=\"ui-id-3\" aria-expanded=\"true\" aria-hidden=\"false\">\n<h2>Specifications<\/h2>\n<ul>\n<li>Backward compatible with previous MVI56-MNETCR versions<\/li>\n<li>Single-slot 1756 ControlLogix backplane compatible<\/li>\n<li>10\/100 Mbps auto crossover detection Ethernet configuration and application port<\/li>\n<li>User-definable module data memory mapping of up to 5000, 16-bit registers<\/li>\n<li>ProSoft Configuration Builder (PCB) software supported, a Windows-based graphical user interface providing simple product and network configuration<\/li>\n<li>Sample ladder logic and Add-On Instructions (AOI) are used for data transfer between module and processor<\/li>\n<li>Internal web server provides access to product documentation, module status, diagnostics, and firmware updates<\/li>\n<li>4-character, alpha-numeric, scrolling LED display of status and diagnostics data in plain English &#8211; no cryptic error or alarm codes to decipher<\/li>\n<li>ProSoft Discovery Service (PDS) software used to locate the module on the network and assign a temporary IP address<\/li>\n<li>Personality Module &#8211; a non-volatile industrial-grade Compact Flash (CF) card used to store network and module configuration for easy disaster recovery, allowing quick in-the-field product replacement by transferring the CF card<\/li>\n<\/ul>\n<\/div>\n<p><strong>NOTE<\/strong>:&nbsp; All products are pre-order items<\/p>\n<p><strong>More:<\/strong>&nbsp; <a href=\"http:\/\/www.prosoft-technology.com\/Products\/Rockwell-Automation-In-chassis\/Platform\/ControlLogix\/Modbus-TCP-IP-Multi-Client-Enhanced-Network-Interface-Module-with-Reduced-Data-Block-for-ControlLogix\" target=\"_blank\" rel=\"noopener\">Specifications, downloads &amp; certifications<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The MVI56E Modbus TCP\/IP Multi-Client Enhanced Communication Module for Remote Chassis allows Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to interface easily with multiple Modbus TCP\/IP server-compatible instruments and devices. The Multi-Client module improves performance when controlling multiple servers on a Modbus TCP\/IP network, by supporting up to 30 clients.<\/p>\n","protected":false},"featured_media":3100,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[583,152,153],"product_tag":[462],"class_list":{"0":"post-1680","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-controllogix","7":"product_cat-prosoft-technology","8":"product_cat-rockwell-automation-in-chassis","9":"product_tag-modbus-tcp-ip-master-slave-enhanced-comm-module-in-remote-chassis-client-only","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/1680","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=1680"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/1680\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/3100"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=1680"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=1680"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=1680"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=1680"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}