{"id":1694,"date":"2017-12-17T10:09:17","date_gmt":"2017-12-17T10:09:17","guid":{"rendered":"http:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=1694"},"modified":"2021-06-19T14:01:21","modified_gmt":"2021-06-19T14:01:21","slug":"ilx69-pbs","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/ilx69-pbs\/","title":{"rendered":"PROFIBUS DPV1 Slave for CompactLogix <br \/><h5>ILX69-PBS<\/h5>"},"content":{"rendered":"<h2>PROFIBUS DPV1 Slave for CompactLogix<\/h2>\n<p>The ILX69 PROFIBUS Slave module is an in-chassis PROFIBUS DPV1 Slave for CompactLogix, supporting cyclic PROFIBUS I\/O data and acyclic messaging.<\/p>\n<p>Explicit ladder logic CIP message blocks provide slave status diagnostic data and the ability for acyclic messaging.The ILX69 interface appears to the CompactLogix controller as a standard I\/O module allowing it to be configured via Studio\/RSLogix\u21225000. The cyclic PROFIBUS I\/O data can be configured in Studio\/RSLogix\u2122 5000, or configuration can be transferred from the Master to the slave module. The Ethernet interface allows for remote diagnostic and troubleshooting. Complete program examples for simple and quick start-up are available.<\/p>\n<h2>Features and Benefits<\/h2>\n<ul>\n<li>Rockwell Automation Encompass Approved<\/li>\n<li>PI Certified<\/li>\n<li>Remote diagnostics via Ethernet<\/li>\n<li>Supports DPV1 Acyclic Messaging<\/li>\n<li>Field-tested with multiple PROFIBUS Masters from multiple vendors<\/li>\n<li>AOP provided to allow for seamless integration to Studio 5000 and RSLogix 5000<\/li>\n<\/ul>\n<h2>Architectures<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-2975\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/ILX69-PBS-Schematic.png\" alt=\"ILX69-PBS-Schematic\" width=\"1386\" height=\"786\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/ILX69-PBS-Schematic.png 1386w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/ILX69-PBS-Schematic-490x278.png 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/ILX69-PBS-Schematic-500x284.png 500w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/ILX69-PBS-Schematic-768x436.png 768w\" sizes=\"(max-width: 1386px) 100vw, 1386px\" \/><\/p>\n<h2>Specifications<\/h2>\n<h2>PROFIBUS DP Specifications<\/h2>\n<table class=\"renderedtable\" width=\"100%\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\"><b>Specification<\/b><\/td>\n<td valign=\"top\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">PROFIBUS DP Cyclic Data<\/td>\n<td valign=\"top\">244 Bytes IN \/ 244 Bytes OUT<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Acyclic Read\/Writes<\/td>\n<td valign=\"top\">240 Bytes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Acyclic communication<\/td>\n<td valign=\"top\">DPV1 Class 1 Read\/Write<br \/>\nDPV1 Class 1 Alarm<br \/>\nDP V1 Class 2 Read\/Write\/Data Transport<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Baud rate<\/td>\n<td valign=\"top\">9.6 kBaud, 19.2 kBaud, 45.45 kBaud, 93.75<br \/>\nkBaud, 187.5 kBaud, 500 kBaud 1.5 MBaud, 3<br \/>\nMBaud, 6 MBaud, 12 MBaudAuto-detection mode is supported<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:\u00a0 All products are pre-order items<\/p>\n<p style=\"text-align: center;\"><strong>More:<\/strong>\u00a0 <a href=\"https:\/\/www.prosoft-technology.com\/Products\/Rockwell-Automation-In-chassis\/Platform\/CompactLogix\/PROFIBUS-DPV1-Slave-for-CompactLogix\">Specifications, downloads &amp; certifications<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The ILX69 PROFIBUS Slave module is an in-chassis PROFIBUS DPV1 Slave for CompactLogix, supporting cyclic PROFIBUS I\/O data and acyclic messaging.<\/p>\n<p>Explicit ladder logic CIP message blocks provide slave status diagnostic data and the ability for acyclic messaging.The ILX69 interface appears to the CompactLogix controller as a standard I\/O module allowing it to be configured via Studio\/RSLogix\u21225000. The cyclic PROFIBUS I\/O data can be configured in Studio\/RSLogix\u2122 5000, or configuration can be transferred from the Master to the slave module.<\/p>\n","protected":false},"featured_media":2976,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[582,152,153],"product_tag":[494],"class_list":{"0":"post-1694","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-compactlogix","7":"product_cat-prosoft-technology","8":"product_cat-rockwell-automation-in-chassis","9":"product_tag-profibus-dpv1-slave-for-compactlogix","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/1694","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=1694"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/1694\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/2976"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=1694"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=1694"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=1694"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=1694"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}