{"id":1701,"date":"2017-12-17T10:40:04","date_gmt":"2017-12-17T10:40:04","guid":{"rendered":"http:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=1701"},"modified":"2017-12-17T11:06:09","modified_gmt":"2017-12-17T11:06:09","slug":"mvi69-pdpmv1","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/mvi69-pdpmv1\/","title":{"rendered":"MVI69-PDPMV1"},"content":{"rendered":"<h2>PROFIBUS DP-V1 Master Network Interface Module for CompactLogix<\/h2>\n<h1>MVI69-PDPMV1<\/h1>\n<p>&nbsp;<\/p>\n<p>The PROFIBUS DPV1 Master module is a powerful communication interface for Rockwell Automation\u00ae CompactLogix \/ MicroLogix\u00ae processors. Developed under license from Rockwell Automation, the module incorporates proprietary backplane technology that enables powerful data exchange with CompactLogix \/ MicroLogix processors.<\/p>\n<p>The module supports complete Master specifications according to IEC 61158. Acyclic parameter data can be transferred with Class 1 or Class 2 DPV1 services, allowing processors to easily communicate with slave devices supporting PROFIBUS DPV0\/V1 protocol.<\/p>\n<p>The module acts as an input\/output module between the PROFIBUS network and the CompactLogix \/ MicroLogix processor. Data transfer from the processor is asynchronous with the I\/O data transfer on the PROFIBUS network.<\/p>\n<p>&nbsp;<\/p>\n<div id=\"features_and_benefits\" class=\"tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom\" role=\"tabpanel\" aria-labelledby=\"ui-id-2\" aria-expanded=\"true\" aria-hidden=\"false\">\n<h2>Features and Benefits<\/h2>\n<ul>\n<li>Single-slot &#8211; 1769 backplane compatible<\/li>\n<li>The module is recognized as an Input\/Output module and has access to processor memory for data transfer between processor and module<\/li>\n<li>Ladder Logic is used for data transfer between module memory and processor controller tags. A sample ladder file with AOI is included<\/li>\n<li>Configuration data obtained from ProSoft Configuration Builder Software, which defines the PROFIBUS network, and then downloads the configuration to the module using the serial port of the PC<\/li>\n<li>Supports CompactLogix and MicroLogix 1500 LRP Controllers except 1769-QBFC1B, 1769-L16x, and 1769-L18x<\/li>\n<\/ul>\n<\/div>\n<p>&nbsp;<\/p>\n<div id=\"applications\" class=\"tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom\" role=\"tabpanel\" aria-labelledby=\"ui-id-3\" aria-expanded=\"true\" aria-hidden=\"false\">\n<h2>Applications<\/h2>\n<p>With the growing usage of the PROFIBUS DPV1 protocol in the industrial marketplace, this product has a wide variety of application uses. Industries that use this technology include:<\/p>\n<ul>\n<li>Power and distribution applications<\/li>\n<li>Petrochemical<\/li>\n<li>Water and Gas Applications<\/li>\n<li>SCADA and DCS applications<\/li>\n<\/ul>\n<\/div>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n<p><strong>NOTE<\/strong>:\u00a0 All products are pre-order items<\/p>\n<div class=\"ui-widget\">\n<div class=\"ui-state-success ui-corner-all\"><strong>Active Mature<\/strong>: Product is fully supported, but a newer product or family exists.<br \/>\nFor new applications use the <a href=\"http:\/\/www.prosoft-technology.com\/Products\/Rockwell-Automation-In-chassis\/Platform\/CompactLogix\/PROFIBUS-DPV1-Master-for-CompactLogix\" target=\"_blank\" rel=\"noopener\">ILX69-PBM<\/a><\/div>\n<div><\/div>\n<\/div>\n<p><strong>More:<\/strong>\u00a0 <a href=\"http:\/\/www.prosoft-technology.com\/Products\/Rockwell-Automation-In-chassis\/Platform\/CompactLogix\/PROFIBUS-DP-V1-Master-Network-Interface-Module-for-CompactLogix\" target=\"_blank\" rel=\"noopener\">Specifications, downloads &amp; certifications<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The PROFIBUS DPV1 Master module is a powerful communication interface for Rockwell Automation\u00ae CompactLogix \/ MicroLogix\u00ae processors. Developed under license from Rockwell Automation, the module incorporates proprietary backplane technology that enables powerful data exchange with CompactLogix \/ MicroLogix processors.<\/p>\n","protected":false},"featured_media":1702,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[173,152,153],"product_tag":[198,202,199],"class_list":{"0":"post-1701","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-profibus","7":"product_cat-prosoft-technology","8":"product_cat-rockwell-automation-in-chassis","9":"product_tag-compactlogix","10":"product_tag-master-network-interface-module","11":"product_tag-profibus-dpv1","13":"first","14":"instock","15":"shipping-taxable","16":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/1701","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=1701"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/1701\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/1702"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=1701"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=1701"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=1701"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=1701"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}