{"id":1726,"date":"2017-12-17T13:20:41","date_gmt":"2017-12-17T13:20:41","guid":{"rendered":"http:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=1726"},"modified":"2021-06-22T17:54:34","modified_gmt":"2021-06-22T17:54:34","slug":"mvi56e-sie","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/mvi56e-sie\/","title":{"rendered":"Siemens Industrial Ethernet Communication Module <br \/><h5>MVI56E-SIE <\/h5>"},"content":{"rendered":"<h2>Siemens Industrial Ethernet Communication Module<\/h2>\n<p>The MVI56E Siemens Industrial Ethernet Communication Module allows Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to interface easily as an Ethernet Client with up to a maximum of 20 Siemens S7-200, S7-1200, S7-300, and S7-400 PLCs operating as Ethernet servers.<\/p>\n<p>The module uses ProSoft Configuration Builder (PCB) which provides a graphical configuration tool for the management of module configuration files, as well as viewing communication and module diagnostic information using the high-speed Ethernet port.<\/p>\n<p>Commands are enabled\/disabled from ladder logic enabling various Siemens S7 CPUs to support multiple applications without having to reconfigure the module. Data transfer to a ControlLogix \u00ae PAC uses scheduled I\/O data for faster updates and better performance.<\/p>\n<h2>Features and Benefits<\/h2>\n<table class=\"renderedtable\" border=\"0\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"150\"><b>Features<\/b><\/td>\n<td valign=\"top\" width=\"550\"><b>Benefits<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"150\">Backward Compatibility<\/td>\n<td valign=\"top\" width=\"550\">\n<ul>\n<li>All MVI56E Enhanced products are backward-compatible with earlier MVI56 modules, allowing direct replacement without the need to change existing controller programs<\/li>\n<li>Enjoy Enhanced features and flexibility without incurring expensive reprogramming costs<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"150\">RSLogix 5000 Integrated<\/td>\n<td valign=\"top\" width=\"550\">\n<ul>\n<li>Module configuration and communication is integrated within RSLogix 5000<\/li>\n<li>No additional programming or configuration software is required<\/li>\n<li>Add-On Instruction for RSLogix 5000 version 16 or higher cuts development time and costs<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"150\">CIPconnect\u00ae-enabled<\/td>\n<td valign=\"top\" width=\"550\">\n<ul>\n<li>ProSoft Configuration Builder software (PCB), with CIPconnect, facilitates remote user access across the ControlLogix backplane through Rockwell Automation&#8217;s 1756-ENBT or 1756-CNBT modules<\/li>\n<li>Configure, diagnose, and analyze process data and communication status<\/li>\n<li>CIPconnect can bridge through multiple ENBT\/CNBT links to connect to MVI56E-MCMs installed in remote chassis for configuration and diagnostics<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"150\">4-digit LED Display<\/td>\n<td valign=\"top\" width=\"550\">\n<ul>\n<li>A scrolling display for easily-understood, plain English diagnostic and error information<\/li>\n<li>See critical configuration and status information without having to hook up to the port<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"250\">Ethernet Port<\/td>\n<td valign=\"top\" width=\"550\">\n<ul>\n<li>Local and remote diagnostics access available through the Ethernet Port<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<ul>\n<li>Single-slot 1756 ControlLogix backplane compatible<\/li>\n<li>10\/100 Mbps auto crossover detection Ethernet configuration and application port<\/li>\n<li>User-definable module data memory mapping of up to 5000 16-bit registers<\/li>\n<li>CIPconnect-enabled network configuration and diagnostics monitoring using ControlLogix 1756-ENxT and 1756-CNB modules and EtherNet\/IP pass-through communication<\/li>\n<li>Add-On Instructions (AOI) are used for data transfer between module and processor<\/li>\n<li>4-character, alpha-numeric, scrolling LED display of status and diagnostics data<\/li>\n<li>ProSoft Discovery Service (PDS) software used to locate the module on the network and assign temporary IP address<\/li>\n<li>Personality Module &#8211; A non-volatile, industrial-grade Compact Flash (CF) card used to store network and module configuration, allowing for quick in-the-field product replacement.<\/li>\n<\/ul>\n<p>Industries that use this technology include:<\/p>\n<ul>\n<li>Power and distribution applications<\/li>\n<li>Petrochemical<\/li>\n<li>Water and Gas Applications<\/li>\n<li>SCADA and DCS applications<\/li>\n<\/ul>\n<h2>Specifications<\/h2>\n<table class=\"renderedtable\" style=\"height: 312px;\" width=\"549\" cellspacing=\"0\" cellpadding=\"5\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"150\"><b>Specification<\/b><\/td>\n<td valign=\"top\" width=\"550\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Supported PLC Data Exchange<br \/>\n(Read and Write)<\/td>\n<td valign=\"top\">Siemens S7-200<br \/>\nSiemens S7-300<br \/>\nSiemens S7-400<br \/>\nSiemens S7-1200<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Supported Register Type<\/td>\n<td valign=\"top\">DB<br \/>\nInputs<br \/>\nOutputs<br \/>\nFlags<br \/>\nCounters<br \/>\nTimers<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Architectures<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-3119\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/Schematic-MVI56E-SIE.png\" alt=\"Schematic MVI56E-SIE\" width=\"1317\" height=\"557\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/Schematic-MVI56E-SIE.png 1317w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/Schematic-MVI56E-SIE-490x207.png 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/Schematic-MVI56E-SIE-500x211.png 500w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/Schematic-MVI56E-SIE-768x325.png 768w\" sizes=\"(max-width: 1317px) 100vw, 1317px\" \/><\/p>\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:\u00a0 All products are pre-order items<\/p>\n<p><!--more--><\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/www.prosoft-technology.com\/Products\/Rockwell-Automation-In-chassis\/Platform\/ControlLogix\/Siemens-Industrial-Ethernet-Communication-Module\" target=\"_blank\" rel=\"noopener\">Specifications, downloads &amp; certifications<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The MVI56E-SIE Siemens Industrial Ethernet Communication Module allows Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to interface easily as an Ethernet Client with up to a maximum of 20 Siemens S7-200, S7-300, S7-400, S7-1200, and S7-1500 PLCs operating as Ethernet servers.<\/p>\n<p>The module uses ProSoft Configuration Builder (PCB) which provides a graphical configuration tool for management of module configuration files, as well as viewing communication and module diagnostic information using the high-speed Ethernet port.\u00a0<\/p>\n<p>Commands are enabled\/disabled from ladder logic enabling various Siemens S7 CPUs to support multiple applications without having to reconfigure the module. Data transfer to a ControlLogix \u00ae PAC uses scheduled I\/O data for faster updates and better performance.<\/p>\n","protected":false},"featured_media":3120,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[583,152,153],"product_tag":[466],"class_list":{"0":"post-1726","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-controllogix","7":"product_cat-prosoft-technology","8":"product_cat-rockwell-automation-in-chassis","9":"product_tag-siemens-industrial-ethernet-communication-module","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/1726","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=1726"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/1726\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/3120"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=1726"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=1726"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=1726"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=1726"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}