{"id":1766,"date":"2017-12-17T17:34:42","date_gmt":"2017-12-17T17:34:42","guid":{"rendered":"http:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=1766"},"modified":"2021-06-14T13:37:05","modified_gmt":"2021-06-14T13:37:05","slug":"mvi69-101s","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/mvi69-101s\/","title":{"rendered":"IEC60870-5-101 Slave Communication Module"},"content":{"rendered":"<div>\n<h2>IEC 60870-5-101 Slave Network Interface Module for CompactLogix<\/h2>\n<p>The MVI69-101S IEC 60870-5-101 Slave Communication Module allows CompactLogixTM and MicroLogixTM 1500 LRP processors to interface easily with IEC 60870-5-101 protocol compatible hosts.<\/p>\n<p>The MVI69-101S module is the fastest and easiest way to add IEC 60870-5-101 protocol interface support to the CompactLogix and MicroLogix 1500 LRPplatforms. It is a single-slot, backplane-compatible solution. It also has two powerful and highly configurable redundant IEC 60870-5-101 slave ports, allowing the many SCADA and field devices supporting the IEC protocol to be integrated into the CompactLogix and MicroLogix 1500 platforms.<\/p>\n<p>&nbsp;<\/p>\n<div id=\"features_and_benefits\" class=\"tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom\" role=\"tabpanel\" aria-labelledby=\"ui-id-1\" aria-expanded=\"true\" aria-hidden=\"false\">\n<h2>Features and Benefits<\/h2>\n<h2>Licensed Backplane Technology<\/h2>\n<ul>\n<li>Manufactured under license from Rockwell Automation<\/li>\n<li>Installs as a Generic 1769 module; sample ladder logic included<\/li>\n<li>View module data and status in RSLogix 5000 controller tags and UDTs<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2>IEC 60870-5-101 slave protocol interface<\/h2>\n<ul>\n<li>The module has two powerful and highly configurable slave ports, allowing the many SCADA and field devices supporting the IEC-101 protocol to be integrated with the processor<\/li>\n<li>The module acts as an input\/output module between the IEC-101 telecontrol network and the processor<\/li>\n<li>The data transfer from the processor is asynchronous from the actions on the network<\/li>\n<li>A 5000-word register space in the module exchanges data between the processor and the telecontrol network<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2>ProSoft Configuration Builder software included<\/h2>\n<ul>\n<li>Graphical drag-and-drop configuration tool for simple module configuration<\/li>\n<li>Easy-to-use diagnostics window with menu-driven hardware and protocol diagnostics<\/li>\n<li>View module database contents through serial connection to a desktop PC<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<h2>Backed by ProSoft Technology<\/h2>\n<ul>\n<li>20-year history of delivering high-quality, reliable solutions designed with you in mind<\/li>\n<li>Free, unlimited, worldwide Technical Support by phone for pre-sale, set-up, or troubleshooting support helps you get going sooner and stay running longer<\/li>\n<li>Three-Year Warranty ensures reliability and protects against equipment failures<\/li>\n<li>Free ProSoft Software tools tightly integrate with our hardware &#8211; A simple and quick, total solution to help you make our products fit your applications<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<p>&nbsp;<\/p>\n<div id=\"general_specs\" class=\"tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom\" role=\"tabpanel\" aria-labelledby=\"ui-id-2\" aria-expanded=\"true\" aria-hidden=\"false\">\n<h2>Specifications<\/h2>\n<ul>\n<li>Single Slot &#8211; 1769 backplane compatible<\/li>\n<li>The module is recognized as an Input\/Output module and has access to processor memory for data transfer between processor and module<\/li>\n<li>Ladder Logic is used for data transfer between module and processor. Sample ladder file included.<\/li>\n<li>Configuration data obtained from configuration text file downloaded to module. Sample configuration file included.<\/li>\n<li>Supports all CompactLogix processors: L20\/L23\/L30\/L31\/L32\/L35, L43 and L45 (L43 and L45 supported with RSLogix 5000 v16.03 or later)<\/li>\n<\/ul>\n<ul>\n<li>Also supports MicroLogix 1500 LRP<\/li>\n<\/ul>\n<\/div>\n<p>&nbsp;<\/p>\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:&nbsp; All products are pre-order items<\/p>\n<p><!--more--><\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/www.prosoft-technology.com\/Products\/Rockwell-Automation-In-chassis\/Platform\/CompactLogix\/IEC-60870-5-101-Slave-Network-Interface-Module-for-CompactLogix\" target=\"_blank\" rel=\"noopener\">Specifications, downloads &amp; certifications<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<h3>MVI69-101S <\/h3>\n<p>The MVI69-101S IEC 60870-5-101 Slave Communication Module allows CompactLogixTM and MicroLogixTM 1500 LRP processors to interface easily with IEC 60870-5-101 protocol compatible hosts.<\/p>\n<p>The MVI69-101S module is the fastest and easiest way to add IEC 60870-5-101 protocol interface support to the CompactLogix and MicroLogix 1500 LRPplatforms. It is a single-slot, backplane compatible solution. It also has two powerful and highly configurable redundant IEC 60870-5-101 slave ports, allowing the many SCADA and field devices supporting the IEC protocol to be integrated into the CompactLogix and MicroLogix 1500 platforms.<\/p>\n","protected":false},"featured_media":1765,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[152,153,177],"product_tag":[478],"class_list":{"0":"post-1766","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-prosoft-technology","7":"product_cat-rockwell-automation-in-chassis","8":"product_cat-specisalised-serial-protocol","9":"product_tag-iec60870-5-101-slave-communication-module","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/1766","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=1766"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/1766\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/1765"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=1766"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=1766"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=1766"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=1766"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}