{"id":1962,"date":"2017-12-21T19:05:54","date_gmt":"2017-12-21T19:05:54","guid":{"rendered":"http:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=1962"},"modified":"2021-06-28T10:30:18","modified_gmt":"2021-06-28T10:30:18","slug":"plx82-mbtcp-pnc","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/plx82-mbtcp-pnc\/","title":{"rendered":"Modbus TCP\/IP to PROFINET Controller Gateway <br \/><h5>PLX82-MBTCP-PNC<\/h5>"},"content":{"rendered":"<h2>Modbus<sup>\u00ae<\/sup> TCP\/IP to PROFINET Controller Gateway<\/h2>\n<p>The Modbus\u00ae TCP\/IP to PROFINET Controller Gateway allows you to connect two giants of industrial automation through secure, high-speed communications. The gateway provides Modbus TCP\/IP-based controllers the ability to control up to 36 PROFINET RT devices such as field I\/O, drives, HMIs, and controllers.<\/p>\n<p>The PLX82-MBTCP-PNC gateways are stand-alone DIN-rail mounted units that provide two Ethernet ports for communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.<\/p>\n<h2>Architectures<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-3255\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX82-MBTCP-PNC-Schematic.jpg\" alt=\"PLX82-MBTCP-PNC Schematic\" width=\"1386\" height=\"786\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX82-MBTCP-PNC-Schematic.jpg 1386w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX82-MBTCP-PNC-Schematic-490x278.jpg 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX82-MBTCP-PNC-Schematic-500x284.jpg 500w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX82-MBTCP-PNC-Schematic-768x436.jpg 768w\" sizes=\"(max-width: 1386px) 100vw, 1386px\" \/><\/p>\n<h2>Features and Benefits<\/h2>\n<ul>\n<li>Isolated Ethernet ports allow devices on different protocols to be on different subnets<\/li>\n<li>PROFINET v2 certification with PROFINET class A compliance<\/li>\n<li>Field-tested with multiple PROFINET devices from multiple vendors<\/li>\n<li>Remotely view and diagnose Modbus TCP\/IP and PROFINET networks<\/li>\n<\/ul>\n<h2><\/h2>\n<h2>Specifications<\/h2>\n<h2><a id=\"eztoc237757_1\" name=\"eztoc237757_1\"><\/a><\/h2>\n<h2><b>Modbus TCP\/IP Specifications<\/b><\/h2>\n<table class=\"renderedtable\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"136\">Supported Modbus Function Codes<\/td>\n<td valign=\"top\" width=\"156\">1: Read Coil Status<\/p>\n<p>2: Read Input Status<\/p>\n<p>3: Read Holding Registers<\/p>\n<p>4: Read Input Registers<\/p>\n<p>5: Force (Write) Single Coil<\/p>\n<p>6: Preset (Write) Single Holding Register<\/td>\n<td valign=\"top\" width=\"174\">15: Force (Write) Multiple Coils<\/p>\n<p>16: Preset (Write) Multiple Holding Registers<\/p>\n<p>22: Mask Write Holding Register (Slave Only)<\/p>\n<p>23: Read\/Write Holding Registers (Slave Only)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Supported Clients<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"330\">10<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Supported Servers<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"330\">MBAP: 5<br \/>\nEncapsulated: 5<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Command List<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"330\">Up to 160 fully configurable Client commands<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Status Data<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"330\">Error codes reported individually for each command<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Command List Polling<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"330\">Each command can be individually enabled or disabled; write-only-on-data-change is available<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><a id=\"eztoc237757_2\" name=\"eztoc237757_2\"><\/a><\/h2>\n<h2><b>PROFINET Specifications<\/b><\/h2>\n<table class=\"renderedtable\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"136\"><b>Specification<\/b><\/td>\n<td valign=\"top\" width=\"330\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Driver Type<\/td>\n<td valign=\"top\" width=\"330\">Class 1 RTC, Class 1 RTA<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">PROFINET I\/O Data<\/td>\n<td valign=\"top\" width=\"330\">3840 bytes IN, 3840 bytes OUT<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Exchange Types<\/td>\n<td valign=\"top\" width=\"330\">Cyclic Real-time (RT) and Acyclic Data<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">PROFINET Devices<\/td>\n<td valign=\"top\" width=\"330\">Max: 36 | Max data per device: 1440 bytes in\/out<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"ui-widget\">\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:\u00a0 All products are pre-order items<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/www.prosoft-technology.com\/Products\/Gateways\/PLX8x\/PLX82-MBTCP-PNC-Modbus-TCP-IP-to-PROFINET-Controller-Gateway\" target=\"_blank\" rel=\"noopener\">Specifications, downloads &amp; certifications<\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The Modbus\u00ae TCP\/IP to PROFINET Controller Gateway allows you to connect two giants of industrial automation through secure, high-speed communications. The gateway provides Modbus TCP\/IP-based controllers the ability to control up to 36 PROFINET RT devices such as field I\/O, drives, HMIs, and controllers.<\/p>\n<p>The PLX82-MBTCP-PNC gateways are stand-alone DIN-rail mounted units that provide two Ethernet ports for communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.<\/p>\n","protected":false},"featured_media":3256,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[291,152,158],"product_tag":[295],"class_list":{"0":"post-1962","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-modbus-tcp-ip-industrial-data-communications-gateways","7":"product_cat-prosoft-technology","8":"product_cat-industrial-data-communications-gateways","9":"product_tag-modbus-tcp-ip-to-profinet-controller-gateway","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/1962","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=1962"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/1962\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/3256"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=1962"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=1962"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=1962"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=1962"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}