{"id":2013,"date":"2017-12-27T05:33:51","date_gmt":"2017-12-27T05:33:51","guid":{"rendered":"http:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=2013"},"modified":"2021-06-28T10:12:27","modified_gmt":"2021-06-28T10:12:27","slug":"plx32-mbtcp-pnd","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/plx32-mbtcp-pnd\/","title":{"rendered":"Modbus TCP\/IP to PROFINET Device Gateway <br \/><h5> PLX32-MBTCP-PND<\/h5>"},"content":{"rendered":"<div>\n<h2>Modbus TCP\/IP to PROFINET Device Gateway<\/h2>\n<p>The Modbus TCP\/IP to PROFINET device gateway offers bi-directional data transfer between a PROFINET Controller and Modbus TCP\/IP networks. The Modbus TCP\/IP driver uses multiple clients and servers for faster data throughput. The PROFINET driver operates as a PROFINET device (slave).<\/p>\n<p>The PLX32-MBTCP-PND gateways are stand-alone DIN-rail mounted units that provide two Ethernet ports for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.<\/p>\n<\/div>\n<h2>Architectures<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-3337\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX32-MBTCP-PND-Schematic.png\" alt=\"PLX32-MBTCP-PND Schematic\" width=\"1386\" height=\"786\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX32-MBTCP-PND-Schematic.png 1386w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX32-MBTCP-PND-Schematic-490x278.png 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX32-MBTCP-PND-Schematic-500x284.png 500w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX32-MBTCP-PND-Schematic-768x436.png 768w\" sizes=\"(max-width: 1386px) 100vw, 1386px\" \/><\/p>\n<h2>Features and Benefits<\/h2>\n<ul>\n<li>PROFINET v2 certification with PROFINET class A compliance<\/li>\n<li>Field-tested with multiple Modbus TCP\/IP devices, and PROFINET controllers from multiple vendors<\/li>\n<li>Remotely view and diagnose Modbus TCP\/IP and PROFINET networks<\/li>\n<li>Remote configuration via the free, intuitive, ProSoft Configuration Builder (PCB) software<\/li>\n<li>Multiple, simultaneous Modbus TCP\/IP client and\/or server connections to allow for increased throughput<\/li>\n<li>Secure module configuration via module switch (v1.04 and greater)<\/li>\n<li>Up to 10,000 16-bit registers can be used to exchange large amounts of data<\/li>\n<\/ul>\n<h2>Specifications<\/h2>\n<h2><a id=\"eztoc210419_0_0_1\" name=\"eztoc210419_0_0_1\"><\/a><\/h2>\n<h4>Modbus TCP\/IP Specifications<\/h4>\n<table class=\"renderedtable\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"126\">Command List<\/td>\n<td colspan=\"3\" valign=\"top\" width=\"336\">Up to 16 commands per client, each fully configurable for Function Code, slave address, register to\/from addressing and word\/bit count.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"126\">Supported Modbus Function Codes<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"161\">1: Read Coil Status<\/p>\n<p>2: Read Input Status<\/p>\n<p>3: Read Holding Registers<\/p>\n<p>4: Read Input Registers<\/p>\n<p>5: Force (Write) Single Coil<\/p>\n<p>6: Preset (Write) Single Holding Register<\/td>\n<td valign=\"top\" width=\"175\">15: Force (Write) Multiple Coils<\/p>\n<p>16: Preset (Write) Multiple Holding Registers<\/p>\n<p>22: Mask Write Holding Register (server only)<\/p>\n<p>23: Read\/Write Holding Registers (server only)<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"132\">Supported clients<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"330\">10<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"132\">Supported servers<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"330\">MBAP = 5, Encapsulated = 5<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"132\">Command List<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"330\">Up to 160 fully configurable client commands<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"132\">Status Data<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"330\">Error codes reported individually for each command<\/td>\n<\/tr>\n<tr>\n<td colspan=\"2\" valign=\"top\" width=\"132\">Command List Polling<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"330\">Each command can be individually enabled or disabled; write-only-on-data-change is available<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"126\"><\/td>\n<td valign=\"top\" width=\"6\"><\/td>\n<td valign=\"top\" width=\"155\"><\/td>\n<td valign=\"top\" width=\"175\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><a id=\"eztoc210419_0_1\" name=\"eztoc210419_0_1\"><\/a><\/h2>\n<h3>PROFINET Specifications<\/h3>\n<table class=\"renderedtable\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"136\">Specification<\/td>\n<td valign=\"top\" width=\"330\">Description<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Driver Type<\/td>\n<td valign=\"top\" width=\"330\">Class A Device<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">PROFINET I\/O Data<\/td>\n<td valign=\"top\" width=\"330\">1440 bytes IN, 1440 bytes OUT<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Exchange Types<\/td>\n<td valign=\"top\" width=\"330\">Cyclic Real-time (RT) and Acyclic Data<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><a id=\"eztoc210419_0_2\" name=\"eztoc210419_0_2\"><\/a><\/h2>\n<h3>Hardware Specifications<\/h3>\n<table class=\"renderedtable\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"136\">Specification<\/td>\n<td valign=\"top\" width=\"330\">Description<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Power Supply<\/td>\n<td valign=\"top\" width=\"330\">24 VDC nominal<br \/>\n10 to 36 VDC allowed<br \/>\nPositive, Negative, GND Terminals<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Current Load<\/td>\n<td valign=\"top\" width=\"330\">24 VDC nominal @ 300 mA<\/p>\n<p>10 to 36 VDC @ 610 mA maximum<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Operating Temperature<\/td>\n<td valign=\"top\" width=\"330\">-25\u00b0C to 70\u00b0C (-13\u00b0F to 158\u00b0F )<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Storage Temperature<\/td>\n<td valign=\"top\" width=\"330\">-40\u00b0C to 80\u00b0C (-40\u00b0F to 176\u00b0F )<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Relative Humidity<\/td>\n<td valign=\"top\" width=\"330\">5% to 95% RH with no condensation<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Shock<\/td>\n<td valign=\"top\" width=\"330\">IEC 60068-2-27; 15G @ 11ms, 3-Axis (Operational)<\/p>\n<p>IEC 60068-2-27; 30G @ 18ms, 3-Axis (Non-Operational)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Vibration<\/td>\n<td valign=\"top\" width=\"330\">IEC 60068-2-6; 5G @ 10 to 150 Hz<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Dimensions<br \/>\n(H x W x D)<\/td>\n<td valign=\"top\" width=\"330\">5.38 x 1.99 x 4.38 in<br \/>\n13.67 x 5.05 \u00a0x 11.13 cm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">LED Indicators<\/td>\n<td valign=\"top\" width=\"330\">*Configuration (CFG)<\/p>\n<p>*Error Status (ERR)<\/p>\n<p>*Power (PWR)<\/p>\n<p>*Hardware Fault (FLT)<\/p>\n<p>*Network Status (NS) Modbus TCP\/IP Class I or Class III Connection Status (Modbus TCP\/IP only)<br \/>\n*Module Status (MS)<\/p>\n<p>*Module Configuration Status (Modbus TCP\/IP only)<br \/>\n*Ethernet Communication Port Link\/Activity and 100mbit<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Ethernet Port<\/td>\n<td valign=\"top\" width=\"330\">*10\/100Mbit RJ45 Connector Electrical Isolation 1500 Vrms at 50 to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991<br \/>\n*Ethernet Broadcast Storm Resiliency &#8211; less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"136\">Shipped With Each Unit<\/td>\n<td valign=\"top\" width=\"330\">2.5 mm screwdriver, J180 Power Connector<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"ui-widget\">\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:\u00a0 All products are pre-order items<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/www.prosoft-technology.com\/Products\/Gateways\/PROFINET\/Modbus-R-TCP-IP-to-PROFINET-R-Device-Gateway-PLX32-MBTCP-PND\" target=\"_blank\" rel=\"noopener\">Specifications, downloads &amp; certifications<\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The Modbus TCP\/IP to PROFINET device gateway offers bi-directional data transfer between a PROFINET Controller and Modbus TCP\/IP networks. The Modbus TCP\/IP driver uses multiple clients and servers for faster data throughput. The PROFINET driver operates as a PROFINET device (slave).<\/p>\n<p>The PLX32-MBTCP-PND gateways are stand-alone DIN-rail mounted units that provide two Ethernet ports for network communications, remote configuration, and diagnostics. The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup.<\/p>\n","protected":false},"featured_media":3338,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[291,152,158],"product_tag":[562],"class_list":{"0":"post-2013","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-modbus-tcp-ip-industrial-data-communications-gateways","7":"product_cat-prosoft-technology","8":"product_cat-industrial-data-communications-gateways","9":"product_tag-modbus-tcp-ip-client-server-to-profinet-device-gateway-for-dual-subnets","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/2013","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=2013"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/2013\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/3338"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=2013"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=2013"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=2013"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=2013"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}