{"id":2016,"date":"2017-12-27T06:04:25","date_gmt":"2017-12-27T06:04:25","guid":{"rendered":"http:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=2016"},"modified":"2021-06-28T10:21:37","modified_gmt":"2021-06-28T10:21:37","slug":"plx32-eip-mbtcp","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/plx32-eip-mbtcp\/","title":{"rendered":"EtherNet\/IP to Modbus TCP\/IP Communications Gateway <br \/><h5>PLX32-EIP-MBTCP<\/h5>"},"content":{"rendered":"<div>\n<h2>EtherNet\/IP to Modbus TCP\/IP Communications Gateway<\/h2>\n<p>ProSoft Technology\u2019s EtherNet\/IP\u2122 to Modbus\u00ae TCP\/IP communication gateway allows high-speed bi-directional data transfers between Rockwell Automation\u00ae PACs and Schneider Electric\u00ae PACs. Our Modbus\u00ae TCP\/IP driver features multiple client and server functionality, for faster data transmission. Two separate Ethernet ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device\u2019s IP address. In addition, the gateway includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.<\/p>\n<p><i>A conformal coating option is available for this product.<\/i><\/p>\n<\/div>\n<h2>Architectures<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-3299\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX32-EIP-MBTCP-Schematic-1.png\" alt=\"PLX32-EIP-MBTCP Schematic-1\" width=\"950\" height=\"599\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX32-EIP-MBTCP-Schematic-1.png 950w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX32-EIP-MBTCP-Schematic-1-490x309.png 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX32-EIP-MBTCP-Schematic-1-500x315.png 500w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX32-EIP-MBTCP-Schematic-1-768x484.png 768w\" sizes=\"(max-width: 950px) 100vw, 950px\" \/><\/p>\n<div id=\"features_and_benefits\" class=\"tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom\" role=\"tabpanel\" aria-labelledby=\"ui-id-2\" aria-expanded=\"true\" aria-hidden=\"false\">\n<h2>Features and Benefits<\/h2>\n<ul>\n<li>Two separate Ethernet ports allow each protocol to reside on separate subnets. This allows you to pass data between the two subnets without changing each device\u2019s IP address to be on the same subnet.<\/li>\n<li>Data prioritization: Multiple I\/O connections allow you to set RPIs for status and\/or control data.<\/li>\n<li>Includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.<\/li>\n<li>Gateway includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery.<\/li>\n<li>Secure module configuration via module switch (v1.04 and greater).<\/li>\n<li>Up to 10,000 16-bit registers can be used to exchange large amounts of data.<\/li>\n<\/ul>\n<\/div>\n<h2>Specifications<\/h2>\n<h2><a id=\"eztoc188486_0_1\" name=\"eztoc188486_0_1\"><\/a><\/h2>\n<h3>EtherNet\/IP\u2122 Specifications<\/h3>\n<table class=\"renderedtable\" border=\"0\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"259\"><b>Specification<\/b><\/td>\n<td valign=\"top\" width=\"366\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"259\">Number of Class 3 Server Connections<\/td>\n<td valign=\"top\" width=\"366\">5<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"259\">Supported PLC Types<\/td>\n<td valign=\"top\" width=\"366\">PLC2, PLC5, SLC, CLX, CMPLX, MICROLX<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"259\">Supported Message Types<\/td>\n<td valign=\"top\" width=\"366\">PCCC and CIP<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"259\">Class 3 Client Connections<\/td>\n<td valign=\"top\" width=\"366\">Connected: 2<br \/>\nUnconnected: 1<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"259\">Number of Class 1 I\/O Connections<\/td>\n<td valign=\"top\" width=\"366\">2<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"259\">I\/O connection sizes<\/td>\n<td valign=\"top\" width=\"366\">248\/248<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"259\">Max RPI time<\/td>\n<td valign=\"top\" width=\"366\">5 ms per connection<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"259\">CIP Services Supported<\/td>\n<td valign=\"top\" width=\"366\">0x4C &#8211; CIP Data Table Read<br \/>\n0x4D &#8211; CIP Data Table Write<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"259\">Command List<\/td>\n<td valign=\"top\" width=\"366\">Support for 100 commands per Client, each configurable for command type, IP address, register to\/from addressing and word\/bit count.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"259\">Command Sets<\/td>\n<td valign=\"top\" width=\"366\">PLC-2\/PLC-3\/PLC5 Basic Command Set<br \/>\nPLC5 Binary Command Set<br \/>\nPLC5 ASCII Command Set<br \/>\nSLC500 Command Set<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><a id=\"eztoc188486_0_2\" name=\"eztoc188486_0_2\"><\/a><\/h2>\n<h3>Modbus\u00ae TCP\/IP Specifications<\/h3>\n<table class=\"renderedtable\" border=\"0\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"228\"><b>Specification<\/b><\/td>\n<td valign=\"top\" width=\"301\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"228\">Supported Modbus Function Codes<\/td>\n<td valign=\"top\" width=\"301\">1: Read Coil Status<br \/>\n2: Read Input Status<br \/>\n3: Read Holding Registers<br \/>\n4: Read Input Registers<br \/>\n5: Force (Write) Single Coil<br \/>\n6: Preset (Write) Single Holding Register<br \/>\n15: Force (Write) Multiple Coils<br \/>\n16: Preset (Write) Multiple Holding Registers<br \/>\n22: Mask Write Holding Register (Slave Only)<br \/>\n23: Read\/Write Holding Registers (Slave Only)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"228\">Supported Clients<\/td>\n<td valign=\"top\" width=\"301\">10<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"228\">Supported Servers<\/td>\n<td valign=\"top\" width=\"301\">MBAP: 5<br \/>\nEncapsulated: 5<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"228\">Command List<\/td>\n<td valign=\"top\" width=\"301\">Up to 160 fully configurable Client commands<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"228\">Status Data<\/td>\n<td valign=\"top\" width=\"301\">Error codes reported individually for each command<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"228\">Command List Polling<\/td>\n<td valign=\"top\" width=\"301\">Each command can be individually enabled or disabled; write-only-on-data-change is available<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"ui-widget\">\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:\u00a0 All products are pre-order items<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/www.prosoft-technology.com\/Products\/Gateways\/PLX3x\/PLX32\/EtherNet-IP-to-Modbus-TCP-IP-Communications-Gateway\" target=\"_blank\" rel=\"noopener\">Specifications, downloads &amp; certifications<\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>ProSoft Technology\u2019s EtherNet\/IP\u2122 to Modbus\u00ae TCP\/IP communication\u00a0gateway allows high-speed bi-directional data transfers between\u00a0Rockwell Automation\u00ae PACs and Schneider Electric\u00ae PACs. Our\u00a0Modbus\u00ae TCP\/IP driver features multiple client and server functionality,\u00a0for faster data transmission. Two separate Ethernet ports allow each\u00a0protocol to reside on separate subnets, allowing you to pass data\u00a0between the two subnets without changing each device\u2019s IP address.\u00a0In addition, the gateway includes an embedded EDS Add-On Profile,\u00a0allowing for simplified integration and reduced commissioning time.<\/p>\n<p><i>A conformal coating option is available for this product.<\/i><\/p>\n","protected":false},"featured_media":3298,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[291,152,158],"product_tag":[565],"class_list":{"0":"post-2016","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-modbus-tcp-ip-industrial-data-communications-gateways","7":"product_cat-prosoft-technology","8":"product_cat-industrial-data-communications-gateways","9":"product_tag-ethernet-ip-to-modbus-tcp-gateway-for-dual-subnets","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/2016","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=2016"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/2016\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/3298"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=2016"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=2016"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=2016"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=2016"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}