{"id":2079,"date":"2017-12-27T12:50:11","date_gmt":"2017-12-27T12:50:11","guid":{"rendered":"http:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=2079"},"modified":"2021-06-28T10:26:16","modified_gmt":"2021-06-28T10:26:16","slug":"plx31-mbtcp-mbs","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/plx31-mbtcp-mbs\/","title":{"rendered":"Modbus TCP\/IP to Modbus Serial Communication Module <br \/><h5>PLX31-MBTCP-MBS<\/h5>"},"content":{"rendered":"<div>\n<h2>Modbus TCP\/IP to Modbus Serial Communication Module<\/h2>\n<p>ProSoft Technology\u2019s Modbus\u00ae TCP\/IP to Modbus\u00ae Serial communication gateway allows high-speed bi-directional data transfers between Modbus\u00ae TCP\/IP-enabled PACs and Modbus\u00ae Serial devices. Modbus\u00ae Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors.<\/p>\n<p>In addition, the gateway has several features that allow simplified integration, reduced commissioning time and optimized performance.<\/p>\n<p><i>A conformal coating option is available for this product.<\/i><\/p>\n<\/div>\n<h2>Architectures<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-3318\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX31-MBTCP-MBS-Schematic.png\" alt=\"PLX31-MBTCP-MBS Schematic\" width=\"600\" height=\"400\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX31-MBTCP-MBS-Schematic.png 600w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX31-MBTCP-MBS-Schematic-490x327.png 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX31-MBTCP-MBS-Schematic-500x333.png 500w\" sizes=\"(max-width: 600px) 100vw, 600px\" \/><\/p>\n<div id=\"features_and_benefits\" class=\"tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom\" role=\"tabpanel\" aria-labelledby=\"ui-id-2\" aria-expanded=\"true\" aria-hidden=\"false\">\n<h2>Features and Benefits<\/h2>\n<ul>\n<li>Supports up to 20 simultaneous client &amp; server connections, allowing for faster communication between devices such as HMIs, SCADA systems, power monitors and flow computers, among others.<\/li>\n<li>Includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery.<\/li>\n<li>ProSoft Discovery Service: This utility allows your PC to see the gateway and change its default IP address without being on the same subnet.<\/li>\n<li>Secure module configuration via module switch (v1.04 and greater).<\/li>\n<li>Up to 10,000 16-bit registers can be used to exchange large amounts of data.<\/li>\n<\/ul>\n<\/div>\n<h2>Specifications<\/h2>\n<p><a id=\"eztoc186289_1\" name=\"eztoc186289_1\"><\/a><\/p>\n<h2><b>Modbus\u00ae TCP\/IP Specifications<\/b><\/h2>\n<table class=\"renderedtable\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"128\"><b>Specification<\/b><\/td>\n<td valign=\"top\" width=\"161\"><b>Description<\/b><\/td>\n<td valign=\"top\" width=\"178\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"128\">Supported Modbus Function Codes<\/td>\n<td valign=\"top\" width=\"161\">1: Read Coil Status<br \/>\n2: Read Input Status<br \/>\n3: Read Holding Registers<br \/>\n4: Read Input Registers<br \/>\n5: Force (Write) Single Coil<br \/>\n6: Preset (Write) Single Holding Register<\/td>\n<td valign=\"top\" width=\"178\">15: Force (Write) Multiple Coils<br \/>\n16: Preset (Write) Multiple Holding Registers<br \/>\n22: Mask Write Holding Register (Slave Only)<br \/>\n23: Read\/Write Holding Registers (Slave Only)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"128\">Supported Clients<\/td>\n<td valign=\"top\" width=\"161\">10<\/td>\n<td valign=\"top\" width=\"178\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"128\">Supported Servers<\/td>\n<td valign=\"top\" width=\"161\">MBAP: 5<br \/>\nEncapsulated: 5<\/td>\n<td valign=\"top\" width=\"178\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"128\">Command List<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"339\">Up to 160 fully configurable Client commands<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"128\">Status Data<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"339\">Error codes reported individually for each command<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"128\">Command List Polling<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"339\">Each command can be individually enabled or disabled;<br \/>\nwrite-only-on-data-change is available<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><a id=\"eztoc186289_2\" name=\"eztoc186289_2\"><\/a><\/p>\n<h2><b>Modbus Serial Specifications<\/b><\/h2>\n<table class=\"renderedtable\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"134\"><b>Specification<\/b><\/td>\n<td valign=\"top\" width=\"153\"><b>Description<\/b><\/td>\n<td valign=\"top\" width=\"179\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"134\">Command List<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"332\">Up to 100 commands per Master port, each fully configurable for Function Code, slave address, register to\/from addressing\u00a0and word\/bit count.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"134\">Supported Modbus Function Codes<\/td>\n<td valign=\"top\" width=\"153\">1: Read Coil Status<br \/>\n2: Read Input Status<br \/>\n3: Read Holding Registers<br \/>\n4: Read Input Registers<br \/>\n5: Force (Write) Single Coil<br \/>\n6: Preset (Write) Single<br \/>\nHolding Register<\/td>\n<td valign=\"top\" width=\"179\">15: Force (Write) Multiple Coils<br \/>\n16: Preset (Write) Multiple Holding Registers<br \/>\n22: Mask Write Holding Register (Slave Only)<br \/>\n23: Read\/Write Holding Registers (Slave Only)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"134\">Software configurable communication parameters<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"332\">Baud rate: 110 baud to 115.2 kbps<br \/>\nParity: None, Even, Odd<br \/>\nData Size: 7 or 8 bits<br \/>\nStop bits: 1 or 2<br \/>\nRTS on\/off delay: 0 to 65535 milliseconds<br \/>\nModbus RTU mode (binary) with CRC-16<br \/>\nModbus ASCII mode with LRC error checking<br \/>\nFloating Point Data Floating point data movement supported, including configurable support for Enron and Daniel implementations<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"134\">Polling of Command List<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"332\">Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic\u00a0enabled.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"134\">Status Data<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"332\">Error codes available on an individual command basis. In\u00a0addition, a slave status list is maintained<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"134\">Node Address<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"332\">1 to 247 (software selectable)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"134\">RS Interface<\/td>\n<td valign=\"top\" width=\"153\">RS232, RS422, and RS485<\/td>\n<td valign=\"top\" width=\"179\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"134\">Transmit and Receive Buffer Size<\/td>\n<td colspan=\"2\" valign=\"top\" width=\"332\">255 byte Transmit character length with 0 to 65535 millisecond delay between each transmitted character<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"ui-widget\">\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:\u00a0 All products are pre-order items<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/www.prosoft-technology.com\/Products\/Gateways\/PLX3x\/PLX31\/Modbus-TCP-IP-to-Modbus-Serial-Communication-Module\">Specifications, downloads &amp; certifications<\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>ProSoft Technology\u2019s Modbus\u00ae TCP\/IP to Modbus\u00ae Serial communication gateway allows high-speed bi-directional data transfers between Modbus\u00ae TCP\/IP-enabled PACs and Modbus\u00ae Serial devices. Modbus\u00ae Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors.<\/p>\n<p>In addition, the gateway has several features that allow simplified integration, reduced commissioning time and optimized performance.<\/p>\n<p><i>A conformal coating option is available for this product.<\/i><\/p>\n","protected":false},"featured_media":3317,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[291,152,158],"product_tag":[571],"class_list":{"0":"post-2079","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-modbus-tcp-ip-industrial-data-communications-gateways","7":"product_cat-prosoft-technology","8":"product_cat-industrial-data-communications-gateways","9":"product_tag-modbus-tcp-to-modbus-serial-gateway","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/2079","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=2079"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/2079\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/3317"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=2079"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=2079"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=2079"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=2079"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}