{"id":2298,"date":"2017-12-28T20:51:39","date_gmt":"2017-12-28T20:51:39","guid":{"rendered":"http:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=2298"},"modified":"2021-06-28T11:00:51","modified_gmt":"2021-06-28T11:00:51","slug":"an-x-amx","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/an-x-amx\/","title":{"rendered":"EtherNet\/IP to Reliance AutoMax Gateway, non-CE <br \/><h5>AN-X-AMX<\/h5>"},"content":{"rendered":"<h2>EtherNet\/IP to Reliance AutoMax Gateway<\/h2>\n<p>The AN-X-AMX Gateway provides a migration path for users looking to upgrade Reliance AutoMax DCS or Remote I\/O networks. The AMX gateway has multiple operating modes, these operating modes are all included with the AN-X-AMX and are selected during the initial module configuration. The operating modes include DCSNet2, a bridge between EtherNet\/IP and a DCSNet network; DCSLOG, for logging DCSNet traffic; AMXRIO, a bridge between EtherNet\/IP and AutoMax Remote I\/O; and AMXCapt, a Remote I\/O or DCSNet data capture tool.<\/p>\n<h2><\/h2>\n<h2>Features and Benefits<\/h2>\n<h2>Migration Specifications<\/h2>\n<h5>DCSNet2<\/h5>\n<p>In the DCSNet2 operating mode, the gateway acts as a bridge between Ethernet\/IP and a Reliance AutoMax DCSNet network. The AN-X removes the hardware dependence on specific AutoMax interface cards (ISA, PCI, PC Card) allowing any computer or PAC with Ethernet\/IP to connect to a DCSNet network.<\/p>\n<ul>\n<li>DCSNet Master or Slave<\/li>\n<li>Supports Reliance AutoMax programming software<\/li>\n<li>Supports up to 15 scheduled connections to a ControlLogix processor, DCSNet2<\/li>\n<li>Supports EtherNet\/IP HMIs to AutoMax controllers<\/li>\n<\/ul>\n<h5>AMXRIO<\/h5>\n<p>In the AMXRIO operating mode, a PC or PAC on Ethernet \/IP can connect to a Reliance AutoMax Remote I\/O network. The module acts as a master on the AutoMax remote I\/O network.<\/p>\n<ul>\n<li>Scan up to 7 slave drops<\/li>\n<li>Supports up to 248 words of scheduled output data and up to 250 words of scheduled input data<\/li>\n<li>Scans AutoMax remote I\/O racks and heads<\/li>\n<li>Maintains diagnostic counters<\/li>\n<\/ul>\n<h2>Troubleshooting Specifications<\/h2>\n<h5>DCSLOG<\/h5>\n<p>In the DCSLOG operating mode, the gateway connects to the AutoMax DCSNet network, listens to every value of each DCSNet register, looks for changes and then timestamps the values.<\/p>\n<ul>\n<li>Data logging with millisecond time stamps<\/li>\n<li>Does not occupy a drop on the network or affect existing network traffic<\/li>\n<\/ul>\n<h5>AMXCAPT<\/h5>\n<p>In the AMXCAPT operating mode, data can be captured, stored, and then analyzed on a Reliance AutoMax DCS or Remote I\/O network. Examine the behavior of all drops, verify network data and timing, locate network errors and troubleshoot problems with the network and with the process.<\/p>\n<ul>\n<li>All network frames are captured and stored, with timestamps to microsecond precision<\/li>\n<li>Post-capture filtering process to select frames of interest for further analysis<\/li>\n<li>Typical capture file size is 2.5 mb\/minute, 150 mb\/hour, 3.6 gb \/day<\/li>\n<\/ul>\n<div class=\"ui-widget\">\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:\u00a0 All products are pre-order items<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/www.prosoft-technology.com\/Products\/Gateways\/EtherNet-IP\/EtherNet-IP-to-Reliance-AutoMax-Gateway-non-CE\">Specifications, downloads &amp; certifications<\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The AN-X-AMX Gateway provides a migration path for users looking to upgrade Reliance AutoMax DCS or Remote I\/O networks. The AMX gateway has multiple operating modes, these operating modes are all included with the AN-X-AMX and are selected during initial module configuration. The operating modes include DCSNet2, a bridge between EtherNet\/IP and a DCSNet network; DCSLOG, for logging DCSNet traffic; AMXRIO, a bridge between EtherNet\/IP and AutoMax Remote I\/O; and AMXCapt, a Remote I\/O or DCSNet data capture tool.<\/p>\n","protected":false},"featured_media":3144,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[161,152,158],"product_tag":[395,581],"class_list":{"0":"post-2298","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-prosoft-ethernet-i-p","7":"product_cat-prosoft-technology","8":"product_cat-industrial-data-communications-gateways","9":"product_tag-ethernet-ip-to-reliance-automax-gateway","10":"product_tag-non-ce","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/2298","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=2298"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/2298\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/3144"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=2298"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=2298"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=2298"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=2298"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}