{"id":2312,"date":"2017-12-29T06:59:38","date_gmt":"2017-12-29T06:59:38","guid":{"rendered":"http:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=2312"},"modified":"2021-06-28T10:02:39","modified_gmt":"2021-06-28T10:02:39","slug":"plx32-eip-pnd","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/plx32-eip-pnd\/","title":{"rendered":"EtherNet\/IP to PROFINET Device Gateway for Dual Subnets <br\/><h5>PLX32-EIP-PND<\/h5>"},"content":{"rendered":"<h2>EtherNet\/IP<sup>\u2122<\/sup> to PROFINET<sup>\u00ae<\/sup> Gateway for dual subnets<\/h2>\n<p>The EtherNet\/IP to PROFINET device gateway offers bi-directional data transfers between a PROFINET Controller and EtherNet\/IP networks. The PLX32-EIP-PND gateway is a stand-alone DIN-rail mounted unit that provides two Ethernet ports, with each port using a different subnet.<\/p>\n<p>The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup. The EtherNet\/IP Driver uses Class 1 I\/O connections or Class 3 Message instructions. The PROFINET driver operates as a PROFINET Class A device.<\/p>\n<p><i>A conformal coating option is available for this product.<\/i><\/p>\n<h2>Architectures<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-3268\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX32-EIP-PND-Schematic.png\" alt=\"PLX32-EIP-PND Schematic\" width=\"950\" height=\"515\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX32-EIP-PND-Schematic.png 950w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX32-EIP-PND-Schematic-490x266.png 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX32-EIP-PND-Schematic-500x271.png 500w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2017\/12\/PLX32-EIP-PND-Schematic-768x416.png 768w\" sizes=\"(max-width: 950px) 100vw, 950px\" \/><\/p>\n<div id=\"features_and_benefits\" class=\"tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom\" role=\"tabpanel\" aria-labelledby=\"ui-id-2\" aria-expanded=\"true\" aria-hidden=\"false\">\n<h2>Features and Benefits<\/h2>\n<ul>\n<li>ODVA Approved<\/li>\n<li>PROFINET v2 certification with PROFINET Class A compliance<\/li>\n<li>EtherNet\/IP and PROFINET certifications ensure the device is compatible with their respective network<\/li>\n<li>Field-tested with multiple PROFINET controllers from multiple vendors<\/li>\n<li>Remotely view and diagnose EtherNet\/IP and PROFINET networks<\/li>\n<li>Embedded EDS AOP provided to allow for seamless integration to Studio 5000 and RSLogix 5000<\/li>\n<li>Using EtherNet\/IP I\/O connections, no ladder programming is required<\/li>\n<li>Multiple I\/O connections to allow for increased throughput<\/li>\n<li>Secure module configuration via module switch (v1.04 and greater)<\/li>\n<li>Up to 10,000 16-bit registers can be used to exchange large amounts of data<\/li>\n<\/ul>\n<\/div>\n<h2><\/h2>\n<h2>Specifications<\/h2>\n<h2><a id=\"eztoc211902_1\" name=\"eztoc211902_1\"><\/a><\/h2>\n<h2><b>EtherNet\/IP\u2122 Specifications<\/b><\/h2>\n<table class=\"renderedtable\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\"><b>Specification<\/b><\/td>\n<td valign=\"top\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of Class 3 Server Connections<\/td>\n<td valign=\"top\">5<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Supported PLC Types<\/td>\n<td valign=\"top\">PLC2, PLC5, SLC, CLX, CMPLX, MICROLX<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Supported Message Types<\/td>\n<td valign=\"top\">PCCC and CIP<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Class 3 Client Connections<\/td>\n<td valign=\"top\">Connected &#8211; 2<\/p>\n<p>Unconnected &#8211; 1<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of Class 1 I\/O Connections<\/td>\n<td valign=\"top\">8<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">I\/O connection sizes in\/out<\/td>\n<td valign=\"top\">496\/496 bytes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Max RPI time<\/td>\n<td valign=\"top\">5 ms per connection<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">CIP Services Supported<\/td>\n<td valign=\"top\">0x4C &#8211; CIP Data Table Read<\/p>\n<p>0x4D &#8211; CIP Data Table Write<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Command List<\/td>\n<td valign=\"top\">Support for 100 commands per Client, each configurable for command type, IP address, register to\/from addressing and word\/bit count.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Command Sets<\/td>\n<td valign=\"top\">PLC-2\/PLC-3\/PLC5 Basic Command Set<\/p>\n<p>PLC5 Binary Command Set<\/p>\n<p>PLC5 ASCII Command Set<\/p>\n<p>SLC500 Command Set<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><a id=\"eztoc211902_2\" name=\"eztoc211902_2\"><\/a><\/h2>\n<h2><\/h2>\n<h2><a id=\"eztoc211902_3\" name=\"eztoc211902_3\"><\/a><\/h2>\n<h2><b>PROFINET Specifications<\/b><\/h2>\n<table class=\"renderedtable\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\"><b>Specification<\/b><\/td>\n<td valign=\"top\"><b>Description<\/b><\/td>\n<td valign=\"top\"><b>\u00a0<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Driver Type<\/td>\n<td colspan=\"2\" valign=\"top\">Class A Device<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">PROFINET I\/O Data<\/td>\n<td colspan=\"2\" valign=\"top\">1440 bytes IN, 1440 bytes OUT<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Exchange Types<\/td>\n<td colspan=\"2\" valign=\"top\">Cyclic Real-time (RT) and Acyclic Data<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2><a id=\"eztoc211902_4\" name=\"eztoc211902_4\"><\/a><\/h2>\n<h2><\/h2>\n<h2><a id=\"eztoc211902_5\" name=\"eztoc211902_5\"><\/a><\/h2>\n<h2><b>Environmental<\/b><\/h2>\n<table class=\"renderedtable\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\"><b>Specification<\/b><\/td>\n<td valign=\"top\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Power Supply<\/td>\n<td valign=\"top\">24 VDC nominal<br \/>\n10 to 36 VDC allowed<br \/>\nPositive, Negative, GND Terminals<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Current Load<\/td>\n<td valign=\"top\">24 VDC nominal @ 300 mA<\/p>\n<p>10 to 36 VDC @ 610 mA maximum<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Operating Temperature<\/td>\n<td valign=\"top\">-25\u00b0C to 70\u00b0C (-13\u00b0F to 158\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Storage Temperature<\/td>\n<td valign=\"top\">-40\u00b0C to 80\u00b0C (-40\u00b0F to 176\u00b0F)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Relative Humidity<\/td>\n<td valign=\"top\">5% to 95% RH with no condensation<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Shock<\/td>\n<td valign=\"top\">IEC 60068-2-27; 15G @ 11ms, 3-Axis (Operational)<\/p>\n<p>IEC 60068-2-27; 30G @ 18ms, 3-Axis (Non-Operation)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Vibration<\/td>\n<td valign=\"top\">IEC 60068-2-6; 5G @ 10Hz to 150Hz<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Dimensions<br \/>\n(H x W x D)<\/td>\n<td valign=\"top\">5.38 x 1.99 x 4.38 in<br \/>\n13.67 x 5.05 x 11.13 cm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Ethernet Ports (2)<\/td>\n<td valign=\"top\">10\/100Mbit RJ45 Connector Electrical Isolation 1500 Vrms at 50 Hz to 60 Hz for 60 seconds, applied as specified in section 5.3.2 of IEC 60950: 1991<br \/>\nEthernet Broadcast Storm Resiliency = less than or equal to 5000 [ARP] frames-per-second and less than or equal to 5 minutes duration<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Shipped With Each Unit<\/td>\n<td valign=\"top\">2.5 mm screwdriver<br \/>\nJ180 Power Connector<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"ui-widget\">\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:\u00a0 All products are pre-order items<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/www.prosoft-technology.com\/Products\/Gateways\/PLX3x\/PLX32\/EtherNet-IP-to-PROFINET-Gateway-for-dual-subnets\" target=\"_blank\" rel=\"noopener\">Specifications, downloads &amp; certifications<\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The EtherNet\/IP to PROFINET device gateway offers bi-directional data transfers between a PROFINET Controller and EtherNet\/IP networks. The PLX32-EIP-PND gateway is a stand-alone DIN-rail mounted unit that provides two Ethernet ports, with each port using a different subnet.<\/p>\n<p>The onboard SD Card slot (SD card optional) is used for storing configuration files that can be used for recovery, transferring the configuration to another gateway, or general configuration backup. The EtherNet\/IP Driver uses Class 1 I\/O connections or Class 3 Message instructions. The PROFINET driver operates as a PROFINET Class A device.<\/p>\n<p><i>A conformal coating option is available for this product.<\/i><\/p>\n","protected":false},"featured_media":3267,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[161,152,158],"product_tag":[564],"class_list":{"0":"post-2312","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-prosoft-ethernet-i-p","7":"product_cat-prosoft-technology","8":"product_cat-industrial-data-communications-gateways","9":"product_tag-ethernet-ip-to-profinet-device-gateway-for-dual-subnets","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/2312","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=2312"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/2312\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/3267"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=2312"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=2312"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=2312"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=2312"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}