{"id":2343,"date":"2017-12-29T13:54:05","date_gmt":"2017-12-29T13:54:05","guid":{"rendered":"http:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=2343"},"modified":"2021-06-28T10:57:44","modified_gmt":"2021-06-28T10:57:44","slug":"an-x-ti","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/an-x-ti\/","title":{"rendered":"EtherNet\/IP to TI500\/505 &#8211; Master; non CE <br \/><h5>AN-X-TI<\/h5>"},"content":{"rendered":"<h2 class=\"product_title entry-title show-product-nav\">EtherNet\/IP to TI500\/505 \u2013 Master; non CE<\/h2>\n<p>The EtherNet\/IP to Texas Instruments Remote I\/O Master gateway allows an Allen-Bradley Programmable Automation Controller (PAC) to control TI 505 Remote I\/O. This gateway allows a phased migration approach to be used when upgrading or replacing TI Remote Base Controllers. The gateway provides automatic creation of the TI Remote I\/O scan-list and generates the associated RSLogix 5000 tags reducing engineering effort. Once the new PAC is commissioned the legacy I\/O can be upgraded one module or one rack at a time as scheduled downtime is available. This gateway minimizes the risk of excessive downtime when upgrading legacy control systems.<\/p>\n<h2><\/h2>\n<h2>Specifications<a id=\"eztoc130523_0_1\" name=\"eztoc130523_0_1\"><\/a><\/h2>\n<h3>TI 505 Features:<\/h3>\n<ul>\n<li>This gateway configures through a web browser (No special configuration software required)<\/li>\n<li>This gateway scans up to 15 Remote I\/O bases and supports both high and low density I\/O modules<\/li>\n<li>Auto-Configuration feature discovers bases and I\/O points reducing configuration errors<\/li>\n<li>Auto-Configuration files are customizable providing additional flexibility for the application and migration phases<\/li>\n<li>Supports offline configuration through a .CSV file<\/li>\n<li>Ability to view configuration and diagnostics through a web browser enabling remote monitoring or troubleshooting<\/li>\n<li>Multi-colored LED that indicates the status of the RIO network connection<\/li>\n<\/ul>\n<table class=\"renderedtable\" width=\"100%\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\"><a id=\"eztoc130523_0_2\" name=\"eztoc130523_0_2\"><\/a><\/p>\n<h3>EtherNet\/IP Features:<\/h3>\n<ul>\n<li>Supports up to 16 Class 1 I\/O connections to reliably transport data to the PAC<\/li>\n<li>Each Class 1 connection can have a unique RPI from 5 &#8211; 750 mSec allowing the PAC to process the I\/O data efficiently<\/li>\n<li>Auto-Configuration feature maps the discovered Modicon I\/O points into tags in the PAC controller<\/li>\n<li>Auto-Configuration files are customizable providing additional flexibility for the application and migration phases<\/li>\n<li>Ability to view configuration and diagnostics through a web browser enabling remote monitoring or troubleshooting<\/li>\n<li>Diagnostic data can be mapped into PAC memory making this ddata available to HMIs<\/li>\n<li>Orange and Green Ethernet network LEDs to show link and activity<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div class=\"ui-widget\">\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:\u00a0 All products are pre-order items<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/www.prosoft-technology.com\/Products\/Gateways\/EtherNet-IP\/EtherNet-IP-to-Texas-Instruments-Remote-I-O-Master-Gateway-non-CE\">Specifications, downloads &amp; certifications<\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The EtherNet\/IP to Texas Instruments Remote I\/O Master gateway allows an Allen-Bradley Programmable Automation Controller (PAC) to control TI 505 Remote I\/O. This gateway allows a phased migration approach to be used when upgrading or replacing TI Remote Base Controllers. The gateway provides automatic creation of the TI Remote I\/O scan-list and generates the associated RSLogix 5000 tags reducing engineering effort. Once the new PAC is commissioned the legacy I\/O can be upgraded one module or one rack at a time as scheduled downtime is available. This gateway minimizes the risk of excessive downtime when upgrading legacy control systems.<\/p>\n","protected":false},"featured_media":3155,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[161,152,158],"product_tag":[549],"class_list":{"0":"post-2343","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-prosoft-ethernet-i-p","7":"product_cat-prosoft-technology","8":"product_cat-industrial-data-communications-gateways","9":"product_tag-ethernet-ip-to-ti500-505-master-non-ce","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/2343","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=2343"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/2343\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/3155"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=2343"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=2343"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=2343"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=2343"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}