{"id":2926,"date":"2021-06-18T10:10:25","date_gmt":"2021-06-18T10:10:25","guid":{"rendered":"http:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=2926"},"modified":"2021-07-04T08:21:51","modified_gmt":"2021-07-04T08:21:51","slug":"ilx56-pbs","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/ilx56-pbs\/","title":{"rendered":"PROFIBUS DPV1 Slave for ControlLogix <br \/><h5>ILX56-PBS<\/h5>"},"content":{"rendered":"<h2>PROFIBUS DPV1 Master\/Slave for ControlLogix<\/h2>\n<p>The ILX56-PBS PROFIBUS DPV1 Multi-Slave module allows Rockwell Automation\u00ae ControlLogix\u00ae processors to communicate on a PROFIBUS DP protocol network by emulating up to 10 individual slave devices.<\/p>\n<p>This multi-slave support of the module provides the ability to pass up to 2440 bytes of input and output data as high-speed cyclic I\/O data on a PROFIBUS DP network.<\/p>\n<p>Combined with the use of multiple I\/O connections back to the ControlLogix processor, this module provides data update rates that will meet even the most demanding of PROFIBUS DP applications.<\/p>\n<p>In addition, with the use of the PLX50 Configuration Utility you have advanced features such as custom-built Add-On Routines and a PROFIBUS DP packet capture utility to minimize the amount of time and effort in getting a ControlLogix PAC operating on a PROFIBUS DP network.<\/p>\n<h2><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-2927\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/ILX56-PBS-Schematic.png\" alt=\"ILX56-PBS Schematic\" width=\"1386\" height=\"786\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/ILX56-PBS-Schematic.png 1386w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/ILX56-PBS-Schematic-490x278.png 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/ILX56-PBS-Schematic-500x284.png 500w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/ILX56-PBS-Schematic-768x436.png 768w\" sizes=\"(max-width: 1386px) 100vw, 1386px\" \/>Features and Benefits<\/h2>\n<ul>\n<li>Rockwell Automation Encompass\u2122-Approved Solution<\/li>\n<li>Remote diagnostics via configuration utility with built-in PROFIBUS DP packet capture utility<\/li>\n<li>Multi-slave mode allows module to emulate up to 10 individual slaves for transfer of up to 2440 bytes of cyclic I\/O data<\/li>\n<li>Supports DPV1 Acyclic Messaging<\/li>\n<li>Add-On Profile and custom Add-On Routines provided to allow for seamless integration to Studio 5000<\/li>\n<\/ul>\n<h2>Specifications<\/h2>\n<p><a id=\"eztoc315125_1\" name=\"eztoc315125_1\"><\/a><\/p>\n<h2>PROFIBUS DP Slave Specifications<\/h2>\n<table class=\"renderedtable\" border=\"0\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"168\"><b>Specification<\/b><\/td>\n<td valign=\"top\" width=\"296\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"168\">Slaves<\/td>\n<td valign=\"top\" width=\"296\">Emulate up to 10&nbsp;individual slaves<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"168\">Input\/Output<\/td>\n<td valign=\"top\" width=\"296\">Maximum 244 Bytes per Slave<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"168\">Input Data<\/td>\n<td valign=\"top\" width=\"296\">Maximum 2440 Bytes&nbsp;(244 per slave)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"168\">Acyclic Data<\/td>\n<td valign=\"top\" width=\"296\">DPV1<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"168\">Status data<\/td>\n<td valign=\"top\" width=\"296\">88 Bytes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"168\">Output data<\/td>\n<td valign=\"top\" width=\"296\">Maximum 2440 Bytes&nbsp;(244 per slave)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"168\">DPV1 Services<\/td>\n<td valign=\"top\" width=\"296\">Class 1 Read\/Write, Class 1 Alarm<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"168\">Services<\/td>\n<td valign=\"top\" width=\"296\">Global-Control, Slave-Diagnostic, Set-Parameter<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"168\">Sync, Freeze Command<\/td>\n<td valign=\"top\" width=\"296\">Supported<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"168\">Baud rate<\/td>\n<td valign=\"top\" width=\"296\">9.6 kBaud, 19.2 kBaud, 45.45 kBaud, 93.75 kBaud, 187.5 kBaud, 500 kBaud, 1.5 MBaud, 3 MBaud, 6 MBaud, 12 MBaud.\n<p>&nbsp;&nbsp;<\/p>\n<p>Auto-detection mode is supported<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;&nbsp;<\/p>\n<p>&nbsp;&nbsp;<\/p>\n<div class=\"ui-widget\">\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:&nbsp; All products are pre-order items<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/www.prosoft-technology.com\/Products\/Rockwell-Automation-In-chassis\/Platform\/ControlLogix\/PROFIBUS-DPV1-Slave-for-ControlLogix\">Specifications, downloads &amp; certifications<\/a><\/p>\n<\/div><p><\/p>","protected":false},"excerpt":{"rendered":"<p>The ILX56-PBS PROFIBUS DPV1 Multi-Slave module allows Rockwell Automation\u00ae ControlLogix\u00ae processors to communicate on a PROFIBUS DP protocol network by emulating up to 10 individual slave devices. This multi-slave support of the module provides the ability to pass up to 2440 bytes of input and output data as high-speed cyclic I\/O data on a PROFIBUS DP network.<\/p>\n","protected":false},"featured_media":3085,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[583,153],"product_tag":[585],"class_list":{"0":"post-2926","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-controllogix","7":"product_cat-rockwell-automation-in-chassis","8":"product_tag-profibus-dpv1-slave-for-controllogix","10":"first","11":"instock","12":"shipping-taxable","13":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/2926","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=2926"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/2926\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/3085"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=2926"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=2926"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=2926"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=2926"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}