{"id":2941,"date":"2021-06-18T15:53:13","date_gmt":"2021-06-18T15:53:13","guid":{"rendered":"http:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=2941"},"modified":"2021-06-22T09:19:58","modified_gmt":"2021-06-22T09:19:58","slug":"mvi56e-mnetr-2","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/mvi56e-mnetr-2\/","title":{"rendered":"Modbus TCP\/IP Client\/Server Enhanced Network Interface Module with Reduced Data Block for ControlLogix <br \/><h5>MVI56E-MNETR<\/h5>"},"content":{"rendered":"<p>The Modbus TCP\/IP Client\/Server Enhanced Communication Module with Reduced Data Block allows Rockwell Automation ControlLogix processors to interface easily with Modbus TCP\/IP-compatible devices, such as Modicon Programmable Automation Controllers (PACs) and a wide variety of Modbus TCP\/IP-compatible instruments and devices.<\/p>\n<p>The MVI56E-MNETR uses a reduced Input\/Output (I\/O) data image block size for transferring data between itself and a ControlLogix processor. This makes it ideal for remote rack applications using ControlNet or EtherNet\/IP process networks. The module also works well for applications that require redundant ControlLogix processors.<\/p>\n<p>MVI56E-MNETR enhancements include local and remote configuration and diagnostics through the module&#8217;s Ethernet port, CIPconnect technology for bridging through Rockwell Automation ControlNet and EtherNetIP networks, and an on-board web server for access to module documentation and sample program files.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-2942\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/Schematic-MVI56E-MNETR.png\" alt=\"Schematic MVI56E MNETR\" width=\"1000\" height=\"567\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/Schematic-MVI56E-MNETR.png 1000w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/Schematic-MVI56E-MNETR-490x278.png 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/Schematic-MVI56E-MNETR-500x284.png 500w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/Schematic-MVI56E-MNETR-768x435.png 768w\" sizes=\"(max-width: 1000px) 100vw, 1000px\" \/><\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-2943\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/Schematic-MVI56E-MNETR_MNETCR.png\" alt=\"\" width=\"1181\" height=\"1023\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/Schematic-MVI56E-MNETR_MNETCR.png 1181w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/Schematic-MVI56E-MNETR_MNETCR-490x424.png 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/Schematic-MVI56E-MNETR_MNETCR-500x433.png 500w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/Schematic-MVI56E-MNETR_MNETCR-768x665.png 768w\" sizes=\"(max-width: 1181px) 100vw, 1181px\" \/><\/p>\n<h2>Features and Benefits<\/h2>\n<table class=\"renderedtable\" cellspacing=\"0\" cellpadding=\"5\" border=\"0\">\n<tbody>\n<tr>\n<td width=\"150\" valign=\"top\">\n<h5>Backward-Compatible<\/h5>\n<\/td>\n<td width=\"550\" valign=\"top\">\n<ul>\n<li>Upgrade earlier MVI56-MNETR modules without changing existing ladder logic programs or module configurations<\/li>\n<li>Enhanced features and flexibility without incurring expensive reprogramming costs<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\" valign=\"top\">RSLogix 5000 Integrated<\/td>\n<td width=\"550\" valign=\"top\">\n<ul>\n<li>Module communication is integrated within RSLogix 5000 using a sample Add-On Instruction (AOI) or sample ladder logic file<\/li>\n<li>No additional programming and\/or configuration software are required<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\" valign=\"top\">Reduced Input\/Output Image Size<\/td>\n<td width=\"550\" valign=\"top\">\n<ul>\n<li>Uses less bandwidth on process control networks like ControlNet or EtherNet\/IP<\/li>\n<li>Optimizes communication for more efficient remote rack installations, especially when using redundant ControlLogix processors<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\" valign=\"top\">Graphical User Interface Software<\/td>\n<td width=\"550\" valign=\"top\">\n<ul>\n<li>ProSoft Configuration Builder (PCB) provides online or offline configuration and online diagnostics using the high-speed Ethernet port<\/li>\n<li>CIPconnect-enabled, allows remote configuration and diagnostic access across multiple bridged EtherNet\/IP and ControlNet networks using Rockwell Automation 1756-ENxT and 1756-CNB network interface modules<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"150\" valign=\"top\">Web-enabled Ethernet port with Discovery Service<\/td>\n<td width=\"550\" valign=\"top\">\n<ul>\n<li>Module&#8217;s built-in Ethernet port provides a web server for local access to documentation, module status, and firmware updates<\/li>\n<li>ProSoft Discovery Service, a software utility to locate MVI56E modules on the network and assign a temporary IP address for easy configuration<\/li>\n<\/ul>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<div id=\"specs\" class=\"tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom\" role=\"tabpanel\" aria-labelledby=\"ui-id-3\" aria-expanded=\"true\" aria-hidden=\"false\">\n<div id=\"specs\" class=\"tabdiv ui-tabs-panel ui-widget-content ui-corner-bottom\" role=\"tabpanel\" aria-labelledby=\"ui-id-3\" aria-expanded=\"true\" aria-hidden=\"false\">\n<h2>Specifications<\/h2>\n<ul>\n<li>Backward-compatible with previous MVI56-MNETR versions<\/li>\n<li>Single-Slot ControlLogix backplane compatible<\/li>\n<li>10\/100 Mbps auto crossover detection Ethernet configuration and application port<\/li>\n<li>User-definable module data memory mapping of up to 5000, 16-bit registers<\/li>\n<li>CIPconnect-enabled network configuration and diagnostics monitoring using ControlLogix 1756-ENxT and 1756-CNB modules and EtherNet\/IP pass-through communication<\/li>\n<li>Reduced I\/O image size designed specifically to optimize remote rack implementations<\/li>\n<li>ProSoft Configuration Builder (PCB) software supported, a Windows-based graphical user interface providing simple product and network configuration<\/li>\n<li>Sample ladder logic and Add-On Instructions (AOIs) are used for data transfer between module and processor<\/li>\n<li>The internal web server provides access to product documentation, module status, diagnostics, and firmware updates<\/li>\n<li>4-character alpha-numeric scrolling LED display of status and diagnostics data in plain English &#8211; no cryptic error or alarm codes to decipher<\/li>\n<li>ProSoft Discovery Service (PDS) software used to locate the module on the network and assign a temporary IP address<\/li>\n<li>Personality Module &#8211; a non-volatile, industrial-grade Compact Flash (CF)card used to store network and module configuration, allowing quick in-the-field product replacement by transferring the CF card<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:&nbsp; All products are pre-order items<\/p>\n<p style=\"text-align: center;\"><strong>More:<\/strong>&nbsp; <a href=\"https:\/\/www.prosoft-technology.com\/Products\/Rockwell-Automation-In-chassis\/Platform\/ControlLogix\/Modbus-TCP-IP-Client-Server-Enhanced-Network-Interface-Module-with-Reduced-Data-Block-for-ControlLogix\">Specifications, downloads &amp; certifications<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>The Modbus TCP\/IP Client\/Server Enhanced Communication Module with Reduced Data Block allows Rockwell Automation ControlLogix processors to interface easily with Modbus TCP\/IP-compatible devices, such as Modicon Programmable Automation Controllers (PACs) and a wide variety of Modbus TCP\/IP-compatible instruments and devices. The MVI56E-MNETR uses a reduced Input\/Output (I\/O) data image block size for transferring data between itself and a ControlLogix processor. This makes it ideal for remote rack applications using ControlNet or EtherNet\/IP process networks. The module also works well for applications that require redundant ControlLogix processors. Which of our Modbus TCP\/IP modules is best for your application? <a href=\"https:\/\/www.youtube.com\/watch?v=fR70cXH8eOA\" target=\"_blank\" rel=\"noopener\">Watch this Video<\/a><\/p>\n","protected":false},"featured_media":3103,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[583,172,152,153],"product_tag":[587],"class_list":{"0":"post-2941","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-controllogix","7":"product_cat-modbus-tcp-ip","8":"product_cat-prosoft-technology","9":"product_cat-rockwell-automation-in-chassis","10":"product_tag-modbus-tcp-ip-client-server-enhanced-network-interface-module-with-reduced-data-block-for-controllogix","12":"first","13":"instock","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/2941","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=2941"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/2941\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/3103"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=2941"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=2941"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=2941"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=2941"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}