{"id":3189,"date":"2021-06-26T11:56:39","date_gmt":"2021-06-26T11:56:39","guid":{"rendered":"https:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=3189"},"modified":"2021-07-04T16:10:36","modified_gmt":"2021-07-04T16:10:36","slug":"a-dntr","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/a-dntr\/","title":{"rendered":"DeviceNet Router<br \/><h5>A-DNTR<\/h5>"},"content":{"rendered":"<p>The DeviceNet Router provides a powerful and easy to configure solution to exchange data between DeviceNet\u2122 devices and a Logix controller or PanelView via EtherNet\/IP\u2122. The module is able to asynchronously exchange data between a DeviceNet polling master (scanner) and an Ethernet PCCC device. Produced and consumed data sizes are independently configurable from 0 to 128 bytes each.<\/p>\n<p>The consumed (DeviceNet) data can then be mapped to a PLC5 type address file, e.g. N33, and then read by an Ethernet device e.g. a PanelView. Similarly, the produced data (DeviceNet) can also be mapped to a PLC5 type address file, to which an Ethernet device could write. The Router supports transferring parameters from a DeviceNet device directly to Logix tags. The scaling of the parameter values will either be extracted from the EDS file imported or can be manually updated by the user. The module also provides a range of statistics and an on-board DeviceNet traffic analyzer to assist with fault finding. A built-in webserver provides detailed diagnostics of system configuration and operation, including the display of DeviceNet operation and communication statistics, without the need for any additional software.<\/p>\n<h2>Architectures<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-3191\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/A-DNTR-DeviceNet-Fig1.png\" alt=\"A-DNTR DeviceNet Fig1\" width=\"547\" height=\"793\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/A-DNTR-DeviceNet-Fig1.png 547w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/A-DNTR-DeviceNet-Fig1-490x710.png 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/A-DNTR-DeviceNet-Fig1-345x500.png 345w\" sizes=\"(max-width: 547px) 100vw, 547px\" \/><\/p>\n<p><img decoding=\"async\" class=\"aligncenter size-full wp-image-3192\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/A-DNTR-DeviceNet-Fig2.png\" alt=\"A-DNTR DeviceNet Fig2\" width=\"562\" height=\"742\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/A-DNTR-DeviceNet-Fig2.png 562w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/A-DNTR-DeviceNet-Fig2-490x647.png 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/A-DNTR-DeviceNet-Fig2-379x500.png 379w\" sizes=\"(max-width: 562px) 100vw, 562px\" \/><\/p>\n<div class=\"ui-widget\">\n<h2><\/h2>\n<h2>Features and Benefits<\/h2>\n<ul>\n<li>DeviceNet to Ethernet Interface<\/li>\n<li>PCCC or EtherNet\/IP protocols<\/li>\n<li>PLC5 Emulation Mode<\/li>\n<li>Direct-to-Tag Technology<\/li>\n<li>Advanced Diagnostics, including packet capture<\/li>\n<\/ul>\n<\/div>\n<h2><\/h2>\n<h2>Configuration<\/h2>\n<p>The Slate Configuration Utility software is used for configuration and troubleshooting of the module. The stand-alone configuration utility allows users to define the setup and configuration of the DeviceNet Router module, connections with controllers and devices.<\/p>\n<div class=\"ui-widget\">\n<p style=\"text-align: center;\"><strong>\u00a0<\/strong><\/p>\n<\/div>\n<div class=\"ui-widget\">\n<p style=\"text-align: center;\"><strong>\u00a0<\/strong><\/p>\n<h2>Specifications<\/h2>\n<p><b>EtherNet\/IP Network<\/b><\/p>\n<table class=\"renderedtable\" border=\"0\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"139\"><b>Specification<\/b><\/td>\n<td valign=\"top\" width=\"139\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"139\">Connector<\/td>\n<td valign=\"top\" width=\"139\">RJ45<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"139\">Conductors<\/td>\n<td valign=\"top\" width=\"139\">CAT5 STP\/UTP<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"139\">ARP Connections<\/td>\n<td valign=\"top\" width=\"139\">Max 20<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"139\">TCP Connections<\/td>\n<td valign=\"top\" width=\"139\">Max 20<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"139\">CIP Connections<\/td>\n<td valign=\"top\" width=\"139\">Max 10<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"139\">Communication Rate<\/td>\n<td valign=\"top\" width=\"139\">10\/100 Mbps<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"139\">Duplex Mode<\/td>\n<td valign=\"top\" width=\"139\">Full \/ Half<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"139\">Auto-MDIX Support<\/td>\n<td valign=\"top\" width=\"139\">Yes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b>DeviceNet Network<\/b><\/p>\n<table class=\"renderedtable\" border=\"0\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"174\"><b>Specification<\/b><\/td>\n<td valign=\"top\" width=\"224\"><b>Rating<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"174\">Connector<\/td>\n<td valign=\"top\" width=\"224\">5-way terminal, 5.08 mm pitch.<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"174\">Conductors<\/td>\n<td valign=\"top\" width=\"224\">12 to 30 AWG<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"174\">Baud Rate<\/td>\n<td valign=\"top\" width=\"224\">125k, 250k, 500k<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"174\">IO Messaging<\/td>\n<td valign=\"top\" width=\"224\">Polled<\/p>\n<p>Change of State (COS)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"174\">Unconnected Message Manager (UCMM)<\/td>\n<td valign=\"top\" width=\"224\">Yes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"174\">Max Explicit Connections<\/td>\n<td valign=\"top\" width=\"224\">5<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b>PCCC Network<\/b><\/p>\n<table class=\"renderedtable\" border=\"0\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"163\"><b>Specification<\/b><\/td>\n<td valign=\"top\" width=\"87\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"163\">Max PCCC Connections<\/td>\n<td valign=\"top\" width=\"87\">10<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"163\">Max PCCC Payload<\/td>\n<td valign=\"top\" width=\"87\">1000 bytes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:\u00a0 All products are pre-order items<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/www.prosoft-technology.com\/Products\/Gateways\/Aparian\/DeviceNet-Router\">Specifications, downloads &amp; certifications<\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The DeviceNet Router provides a powerful and easy to configure solution to exchange data between DeviceNet\u2122 devices and a Logix controller or PanelView via EtherNet\/IP\u2122. The module is able to asynchronously exchange data between a DeviceNet polling master (scanner) and an Ethernet PCCC device. Produced and consumed data sizes are independently configurable from 0 to 128 bytes each.<\/p>\n<p>The consumed (DeviceNet) data can then be mapped to a PLC5 type address file, e.g. N33, and then read by an Ethernet device e.g. a PanelView. Similarly, the produced data (DeviceNet) can also be mapped to a PLC5 type address file, to which an Ethernet device could write. The Router supports transferring parameters from a DeviceNet device directly to Logix tags. The scaling of the parameter values will either be extracted from the EDS file imported or can be manually updated by the user. The module also provides a range of statistics and an on-board DeviceNet traffic analyzer to assist with fault finding. A built-in webserver provides detailed diagnostics of system configuration and operation, including the display of DeviceNet operation and communication statistics, without the need for any additional software.<\/p>\n","protected":false},"featured_media":3190,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[161,152,158],"product_tag":[640],"class_list":{"0":"post-3189","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-prosoft-ethernet-i-p","7":"product_cat-prosoft-technology","8":"product_cat-industrial-data-communications-gateways","9":"product_tag-devicenet-router","11":"first","12":"instock","13":"featured","14":"shipping-taxable","15":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/3189","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=3189"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/3189\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/3190"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=3189"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=3189"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=3189"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=3189"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}