{"id":3200,"date":"2021-06-26T16:53:19","date_gmt":"2021-06-26T16:53:19","guid":{"rendered":"https:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=3200"},"modified":"2021-06-28T09:58:14","modified_gmt":"2021-06-28T09:58:14","slug":"plx32-mbtcp-104","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/plx32-mbtcp-104\/","title":{"rendered":"Modbus TCP\/IP to IEC 60870-5-104 Gateway<br \/><h5>PLX32-MBTCP-104<\/h5>"},"content":{"rendered":"<p>Integration of Modbus TCP\/IP\u00ae products into IEC 60870-5-104 networks can be a challenge, but not with ProSoft Technology\u2019s PLX32-MBTCP-104 gateway.<\/p>\n<p>The gateway has dual Ethernet ports, providing the option to have one Ethernet port communicating on both Modbus TCP\/IP and IEC 60870-5-104 networks, or independent communication ports for each protocol.<\/p>\n<p>The gateway provides powerful communications on the Modbus TCP\/IP network, operating as either a Client or a Server to various devices such as PLC\u2019s, Drives, HMI\u2019s and various other equipment supporting the Modbus TCP\/IP protocol.<\/p>\n<p>On the IEC 60870-5-104 side of the communications, the gateway operates as a server, accepting commands from client devices such as a SCADA system or DCS system.<\/p>\n<h2>Architectures<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-3202\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/PLX32-MBTCP-104-schematic01.png\" alt=\"PLX32-MBTCP-104 schematic01\" width=\"1152\" height=\"778\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/PLX32-MBTCP-104-schematic01.png 1152w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/PLX32-MBTCP-104-schematic01-490x331.png 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/PLX32-MBTCP-104-schematic01-500x338.png 500w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/PLX32-MBTCP-104-schematic01-768x519.png 768w\" sizes=\"(max-width: 1152px) 100vw, 1152px\" \/><\/p>\n<div class=\"ui-widget\">\n<h2><img decoding=\"async\" class=\"aligncenter size-full wp-image-3203\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/PLX32-MBTCP-104-schematic02.png\" alt=\"PLX32-MBTCP-104 schematic02\" width=\"1153\" height=\"778\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/PLX32-MBTCP-104-schematic02.png 1153w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/PLX32-MBTCP-104-schematic02-490x331.png 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/PLX32-MBTCP-104-schematic02-500x337.png 500w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/PLX32-MBTCP-104-schematic02-768x518.png 768w\" sizes=\"(max-width: 1153px) 100vw, 1153px\" \/><\/h2>\n<h2>Features and Benefits<\/h2>\n<ul>\n<li>Up to 10,000 words of user-defined memory to share data between IEC 60870-5-104 and Modbus TCP\/IP networks<\/li>\n<li>Up to 1000 points of each supported ASDU type can be exchanged on the IEC-60870-5-104 network<\/li>\n<li>Modbus TCP\/IP support as both Client (Master) and Server (Slave)<\/li>\n<li>Ability to operate using one Ethernet port, or 2 individual Ethernet ports<\/li>\n<li>Upload, Download, Diagnostics via ProSoft Configuration Builder (PCB) via an Ethernet connection<\/li>\n<li>Configurable Common ASDU address (sector) and Information Object Address for IEC 60870-5-104 application<\/li>\n<li>Optional support for SD card for configuration storage (Sold separately)<\/li>\n<\/ul>\n<\/div>\n<h2><\/h2>\n<h2>Configuration<\/h2>\n<p>The Slate Configuration Utility software is used for configuration and troubleshooting of the module. The stand-alone configuration utility allows users to define the setup and configuration of the J1939 Router module, connections with controllers and devices.<\/p>\n<div class=\"ui-widget\">\n<p style=\"text-align: center;\"><strong>\u00a0<\/strong><\/p>\n<\/div>\n<div class=\"ui-widget\">\n<p style=\"text-align: center;\"><strong>\u00a0<\/strong><\/p>\n<h2>Specifications<\/h2>\n<p><b>Modbus TCP\/IP Specifications\u00a0<\/b><\/p>\n<table class=\"renderedtable\" border=\"0\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"289\"><b>Specification<\/b><\/td>\n<td valign=\"top\" width=\"228\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"289\">Number of Modbus TCP\/IP Client Connections<\/td>\n<td valign=\"top\" width=\"228\">10<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"289\">Supported Function Codes<\/td>\n<td valign=\"top\" width=\"228\">1,2,3,4,5,6,15, and 16<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"289\">Number of Modbus TCP\/IP Client Commands<\/td>\n<td valign=\"top\" width=\"228\">16 each client connection<br \/>\n160 total<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"289\">Number of Modbus TCP\/IP Server Connections<\/td>\n<td valign=\"top\" width=\"228\">5 Simultaneous Server connections<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><b>IEC 60870-5-104 Server\u00a0<\/b><\/p>\n<table class=\"renderedtable\" border=\"0\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"203\"><b>Specification<\/b><\/td>\n<td valign=\"top\" width=\"203\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"203\">Operating Mode<\/td>\n<td valign=\"top\" width=\"203\">IEC 60870-5-104 Server<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"203\">Simultaneous Connections<\/td>\n<td valign=\"top\" width=\"203\">3<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"203\">Unsolicited Messaging<\/td>\n<td valign=\"top\" width=\"203\">Either cyclic or spontaneous<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"203\">Group Interrogation<\/td>\n<td valign=\"top\" width=\"203\">Global, General 1 to 16, Global Counters, Counters 1 to 4<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"203\">Supported ASDU types<\/td>\n<td valign=\"top\" width=\"203\">Up to a maximum of 1000 of each of the following ASDU types are supported: M_SP_NA, M_DP_NA, M_ST_NA, M_ME_NA, M_ME_NB, M_ME_NC, M_IT_NA, C_SC_NA, C_DC_NA, C_RC_NA, C_SE_NA, C_SE_NB, C_SE_NC<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:\u00a0 All products are pre-order items<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/www.prosoft-technology.com\/Products\/Gateways\/PLX3x\/PLX32\/Modbus-TCP-IP-to-IEC-60870-5-104-Gateway\" target=\"_blank\" rel=\"noopener\">Specifications, downloads &amp; certifications<\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Integration of Modbus TCP\/IP\u00ae products into IEC 60870-5-104 networks can be a challenge, but not with ProSoft Technology\u2019s PLX32-MBTCP-104 gateway.<\/p>\n<p>The gateway has dual Ethernet ports, providing the option to have one Ethernet port communicating on both Modbus TCP\/IP and IEC 60870-5-104 networks, or independent communication ports for each protocol.<\/p>\n<p>The gateway provides powerful communications on the Modbus TCP\/IP network, operating as either a Client or a Server to various devices such as PLC\u2019s, Drives, HMI\u2019s and various other equipment supporting the Modbus TCP\/IP protocol.<\/p>\n","protected":false},"featured_media":3201,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[161,152,158],"product_tag":[632],"class_list":{"0":"post-3200","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-prosoft-ethernet-i-p","7":"product_cat-prosoft-technology","8":"product_cat-industrial-data-communications-gateways","9":"product_tag-modbus-tcp-ip-to-iec-60870-5-104-gateway","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/3200","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=3200"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/3200\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/3201"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=3200"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=3200"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=3200"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=3200"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}