{"id":3209,"date":"2021-06-26T17:59:39","date_gmt":"2021-06-26T17:59:39","guid":{"rendered":"https:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=3209"},"modified":"2021-06-28T10:48:33","modified_gmt":"2021-06-28T10:48:33","slug":"plx51-dlplus-232","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/plx51-dlplus-232\/","title":{"rendered":"Data Logger Plus<br \/><h5>PLX51-DLplus-232<\/h5>"},"content":{"rendered":"<h3>Data Logger Plus<\/h3>\n<p>The PLX51-DLplus-232 Data Logger is ideal for remote sites with limited communications that need to log data. OEMs can log their machine\u2019s data to identify operational problems or efficiency improvements and can view this data online as trends via an integrated webserver. The trend data can be exported as a CSV file. The module supports REST API to collect JSON encoded data from the module that can be sent to other systems.<\/p>\n<p>The PLX51-DLplus-232 can read and store data from EtherNet\/IP\u2122 PLCs, DF1 Serial PLCs and devices, or Modbus\u00ae PLCs and devices. The PLX51-DLplus-232 has the capacity to store over 16 million records in its solid-state non-volatile memory. Each stored record includes a Date Time stamp, Tag Name, Data Type, and Value.<\/p>\n<p>Learn more about\u00a0<b><a title=\"Secure Remote Connectivity Solutions\" href=\"https:\/\/www.prosoft-technology.com\/Landing-Pages\/Secure_Remote_Connectivity\" target=\"_blank\" rel=\"noopener\">ProSoft\u2019s Remote Connectivity Solutions<\/a><\/b>.<\/p>\n<h2><\/h2>\n<h2>Architectures<\/h2>\n<div class=\"ui-widget\"><\/div>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-3211\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/schematic_PLX51-DLplus-232.jpg\" alt=\"schematic PLX51 DLplus-232\" width=\"900\" height=\"602\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/schematic_PLX51-DLplus-232.jpg 900w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/schematic_PLX51-DLplus-232-490x328.jpg 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/schematic_PLX51-DLplus-232-500x334.jpg 500w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/schematic_PLX51-DLplus-232-768x514.jpg 768w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/p>\n<div class=\"ui-widget\">\n<h2><\/h2>\n<h2>Features and Benefits<\/h2>\n<ul>\n<li>A built in web server to trend up to five (5) user defined variables with configurable time period<\/li>\n<li>REST API to collect JSON-encoded data and send to other systems<\/li>\n<li>Stored data can be downloaded to a CSV file via the webserver or manually using the PLX50 Configuration Utility<\/li>\n<li>A built-in webserver provides detailed diagnostics of system configuration and operation<\/li>\n<li>Two logging modes: Data stored until memory is full or oldest data overwritten when memory is full &#8211; First in, First out<\/li>\n<\/ul>\n<\/div>\n<div class=\"ui-widget\">\n<p style=\"text-align: center;\"><strong>\u00a0<\/strong><\/p>\n<\/div>\n<div class=\"ui-widget\">\n<p style=\"text-align: center;\"><strong>\u00a0<\/strong><\/p>\n<p style=\"text-align: center;\"><strong>\u00a0<\/strong><\/p>\n<p style=\"text-align: center;\"><strong>\u00a0<\/strong><\/p>\n<h2>Specifications<\/h2>\n<table class=\"renderedtable\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"224\"><b>EtherNet\/IP<\/b><\/td>\n<td valign=\"top\" width=\"224\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Connector<\/td>\n<td valign=\"top\" width=\"224\">RJ45<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Conductors<\/td>\n<td valign=\"top\" width=\"224\">CAT5 STP\/UTP<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">ARP Connections<\/td>\n<td valign=\"top\" width=\"224\">Max 20<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">TCP Connections<\/td>\n<td valign=\"top\" width=\"224\">Max 20<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">CIP Connections<\/td>\n<td valign=\"top\" width=\"224\">Max 10<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Communication Rate<\/td>\n<td valign=\"top\" width=\"224\">10\/100 Mbps<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Duplex Mode<\/td>\n<td valign=\"top\" width=\"224\">Full \/ Half<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Auto MDIX<\/td>\n<td valign=\"top\" width=\"224\">Yes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\"><\/td>\n<td valign=\"top\" width=\"224\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\"><b>Serial Port<\/b><\/td>\n<td valign=\"top\" width=\"224\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Baud Rate<\/td>\n<td valign=\"top\" width=\"224\">1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Parity<\/td>\n<td valign=\"top\" width=\"224\">None, Even, Odd<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Data Bits<\/td>\n<td valign=\"top\" width=\"224\">8<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Stop Bits<\/td>\n<td valign=\"top\" width=\"224\">1<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">RS232 Connector<\/td>\n<td valign=\"top\" width=\"224\">4-way terminal<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">RS232 Conductor<\/td>\n<td valign=\"top\" width=\"224\">24 to 18 AWG<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">RS232 Isolation Voltage<\/td>\n<td valign=\"top\" width=\"224\">2.5 kV<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\"><\/td>\n<td valign=\"top\" width=\"224\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\"><b>DF1<\/b><\/td>\n<td valign=\"top\" width=\"224\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Protocol<\/td>\n<td valign=\"top\" width=\"224\">DF1 Full Duplex, DF1 Half Duplex<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Error Detection<\/td>\n<td valign=\"top\" width=\"224\">CRC, BCC<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Embedded Response<\/td>\n<td valign=\"top\" width=\"224\">Auto, On<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\"><\/td>\n<td valign=\"top\" width=\"224\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\"><b>Modbus<\/b><\/td>\n<td valign=\"top\" width=\"224\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Protocol<\/td>\n<td valign=\"top\" width=\"224\">Modbus RTU, Modbus TCP\/IP<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Function Codes Supported<\/td>\n<td valign=\"top\" width=\"224\">1: Read Coils<\/p>\n<p>2: Read Discrete Inputs<\/p>\n<p>3: Read Holding Registers<\/p>\n<p>4: Read Input Registers<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\"><\/td>\n<td valign=\"top\" width=\"224\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\"><b>Data Logging<\/b><\/td>\n<td valign=\"top\" width=\"224\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Max Record Count<\/td>\n<td valign=\"top\" width=\"224\">16,777,216<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Max Tag Count<\/td>\n<td valign=\"top\" width=\"224\">200<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Log Criteria Supported<\/td>\n<td valign=\"top\" width=\"224\">Delta Change, Heartbeat, Tag Triggers<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Min Log Interval<\/td>\n<td valign=\"top\" width=\"224\">50 ms<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Data Types Supported<\/td>\n<td valign=\"top\" width=\"224\">BOOL, SINT, INT, DINT REAL<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Cached Records (Non-Volatile)<\/td>\n<td valign=\"top\" width=\"224\">Yes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Log Triggers Supported<\/td>\n<td valign=\"top\" width=\"224\">Yes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Data Sources<\/td>\n<td valign=\"top\" width=\"224\">Logix Tags, DF1 File, Modbus (RTU and TCP\/IP)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\"><\/td>\n<td valign=\"top\" width=\"224\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\"><b>Data Trends Report<\/b><\/td>\n<td valign=\"top\" width=\"224\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Max Objects<\/td>\n<td valign=\"top\" width=\"224\">5<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Max number of records<\/td>\n<td valign=\"top\" width=\"224\">10,000 per object<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Upload to CSV<\/td>\n<td valign=\"top\" width=\"224\">Yes, up to 1,000,000 records per object<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Configure Tags<\/td>\n<td valign=\"top\" width=\"224\">Yes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">Configure Scaling<\/td>\n<td valign=\"top\" width=\"224\">Yes<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\"><\/td>\n<td valign=\"top\" width=\"224\"><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\"><b>REST API Support<\/b><\/td>\n<td valign=\"top\" width=\"224\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"224\">JSON-encoded messages<\/td>\n<td valign=\"top\" width=\"224\">Yes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:\u00a0 All products are pre-order items<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/www.prosoft-technology.com\/Products\/Gateways\/PLX5x\/Data-Logger-Plus\">Specifications, downloads &amp; certifications<\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>The PLX51-DLplus-232 Data Logger is ideal for remote sites with limited communications that need to log data. OEMs can log their machine\u2019s data to identify operational problems or efficiency improvements and can view this data online as trends via an integrated webserver. The trend data can be exported as a CSV file. The module supports REST API to collect JSON encoded data from the module that can be sent to other systems.<\/p>\n<p>The PLX51-DLplus-232 can read and store data from EtherNet\/IP\u2122 PLCs, DF1 Serial PLCs and devices, or Modbus\u00ae PLCs and devices. The PLX51-DLplus-232 has the capacity to store over 16 million records in its solid-state non-volatile memory. Each stored record includes a Date Time stamp, Tag Name, Data Type, and Value.<\/p>\n<p>Learn more about\u00a0<b><a title=\"Secure Remote Connectivity Solutions\" href=\"https:\/\/www.prosoft-technology.com\/Landing-Pages\/Secure_Remote_Connectivity\" target=\"_blank\" rel=\"noopener\">ProSoft\u2019s Remote Connectivity Solutions<\/a><\/b>.<\/p>\n","protected":false},"featured_media":3210,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[161,152,158],"product_tag":[637],"class_list":{"0":"post-3209","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-prosoft-ethernet-i-p","7":"product_cat-prosoft-technology","8":"product_cat-industrial-data-communications-gateways","9":"product_tag-data-logger-plus","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/3209","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=3209"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/3209\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/3210"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=3209"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=3209"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=3209"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=3209"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}