{"id":3228,"date":"2021-06-26T19:23:15","date_gmt":"2021-06-26T19:23:15","guid":{"rendered":"https:\/\/www.throughput.co.za\/products\/?post_type=product&#038;p=3228"},"modified":"2021-06-28T10:00:25","modified_gmt":"2021-06-28T10:00:25","slug":"plx32-eip-mbtcp-ua","status":"publish","type":"product","link":"https:\/\/www.throughput.co.za\/products\/product\/plx32-eip-mbtcp-ua\/","title":{"rendered":"EtherNet\/IP to Modbus TCP\/IP to OPC UA Server Gateway <br\/><h5>PLX32-EIP-MBTCP-UA<\/h5>"},"content":{"rendered":"<h3>EtherNet\/IP to Modbus TCP\/IP to OPC UA Server Gateway<\/h3>\n<p>Need to get data from your EtherNet\/IP\u2122 or Modbus\u00ae TCP\/IP-based devices to your OPC UA clients to be analyzed so you can reduce your operating costs or increase your production?<\/p>\n<p>ProSoft Technology\u2019s EtherNet\/IP to Modbus TCP\/IP to OPC UA Server communication gateway allows high-speed tri-directional data transfers between EtherNet\/IP PACs and Modbus TCP\/IP devices, while also providing an OPC UA Server connection.<\/p>\n<p>The Modbus TCP\/IP driver features multiple, simultaneous client and server connections for faster data transmission. For simplified integration and reduced commissioning time for Rockwell Automation\u00ae EtherNet\/IP-enabled PACs, an EDS AOP is provided.<\/p>\n<p>The highly reliable and secure OPC UA Server supports 10 simultaneous OPC UA sessions that provide access to EtherNet\/IP and Modbus TCP\/IP data from the respective networks.<\/p>\n<h2><\/h2>\n<h2>Architectures<\/h2>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-3229\" src=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/PLX32-EIP-MBTCP-UA-Schematic.jpg\" alt=\"PLX32-EIP-MBTCP-UA Schematic\" width=\"1015\" height=\"642\" srcset=\"https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/PLX32-EIP-MBTCP-UA-Schematic.jpg 1015w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/PLX32-EIP-MBTCP-UA-Schematic-490x310.jpg 490w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/PLX32-EIP-MBTCP-UA-Schematic-500x316.jpg 500w, https:\/\/www.throughput.co.za\/products\/wp-content\/uploads\/2021\/06\/PLX32-EIP-MBTCP-UA-Schematic-768x486.jpg 768w\" sizes=\"(max-width: 1015px) 100vw, 1015px\" \/><\/p>\n<h2><\/h2>\n<h2><\/h2>\n<h2>Features and Benefits<\/h2>\n<ul>\n<li>Two separate Ethernet ports allow EtherNet\/IP and Modbus TCP\/IP to reside on a different subnet than the OPC UA Server.<\/li>\n<li>All three protocols operate independently and simultaneously while accessing common process data.<\/li>\n<li>Data prioritization: Multiple EtherNet\/IP I\/O connections allow for different RPIs for status and\/or control data.<\/li>\n<li>Includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.<\/li>\n<li>Gateway includes an SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery.<\/li>\n<\/ul>\n<h2><\/h2>\n<div class=\"ui-widget\">\n<p style=\"text-align: center;\"><strong>\u00a0<\/strong><\/p>\n<h2>Specifications<\/h2>\n<p style=\"text-align: center;\"><strong><a id=\"eztoc244797_1\" name=\"eztoc244797_1\"><\/a><\/strong><\/p>\n<h3>EtherNet\/IP\u2122 Specifications<\/h3>\n<table class=\"renderedtable\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\"><b>Specification<\/b><\/td>\n<td valign=\"top\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of Class 3 Server Connections<\/td>\n<td valign=\"top\">5<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Supported Message Types<\/td>\n<td valign=\"top\">PCCC and CIP<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Class 3 Client Connections<\/td>\n<td valign=\"top\">Connected: 2<\/p>\n<p>Unconnected: 1<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Number of Class 1 I\/O<\/p>\n<p>Connections<\/td>\n<td valign=\"top\">8<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">I\/O connection sizes<\/td>\n<td valign=\"top\">248\/248<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Max RPI time<\/td>\n<td valign=\"top\">5 ms per connection<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">CIP Services Supported<\/td>\n<td valign=\"top\">0x4C: CIP Data Table Read<\/p>\n<p>0x4D: CIP Data Table Write<\/p>\n<p>CIP Generic<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Command List<\/td>\n<td valign=\"top\">Support for 100 commands (Class 3 MSG) per Client<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Command Sets<\/td>\n<td valign=\"top\">PLC-2\/PLC-3\/PLC5\/SLC500<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: center;\"><strong><a id=\"eztoc244797_2\" name=\"eztoc244797_2\"><\/a><\/strong><\/p>\n<h3>Modbus\u00a0TCP\/IP Specifications<\/h3>\n<table class=\"renderedtable\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\" width=\"228\"><b>Specification<\/b><\/td>\n<td valign=\"top\" width=\"228\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"228\">Supported Function Codes<\/td>\n<td valign=\"top\" width=\"228\">1, 2, 3, 4, 5, 6, 15, 16, 22 and 23 (Slave only)<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"228\">Supported Clients<\/td>\n<td valign=\"top\" width=\"228\">10<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"228\">Supported Servers<\/td>\n<td valign=\"top\" width=\"228\">MBAP: 5<\/p>\n<p>Encapsulated: 5<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"228\">Command List<\/td>\n<td valign=\"top\" width=\"228\">Up to 160 fully configurable Client commands<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"228\">Status Data<\/td>\n<td valign=\"top\" width=\"228\">Error codes reported individually for each command<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\" width=\"228\">Command List Polling<\/td>\n<td valign=\"top\" width=\"228\">Each command can be individually enabled or disabled; write-only-on-data-change is available<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: center;\"><strong><a id=\"eztoc244797_3\" name=\"eztoc244797_3\"><\/a><\/strong><\/p>\n<h3>OPC UA Server<\/h3>\n<table class=\"renderedtable\" cellspacing=\"0\" cellpadding=\"2\">\n<tbody>\n<tr>\n<td valign=\"top\"><b>Specification<\/b><\/td>\n<td valign=\"top\"><b>Description<\/b><\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Client Connections<\/td>\n<td valign=\"top\">10 simultaneous connections supported<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Security<\/td>\n<td valign=\"top\">Sign, Sign and Encrypt with policies Basic256Sha256,<\/p>\n<p>Basic256 and Basic128Rsa15, and None<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Transport protocol \/ encoding<\/td>\n<td valign=\"top\">opc.tcp \/ binary<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">User authentication and authorization<\/td>\n<td valign=\"top\">User name\/Password based authentication and Role based authorization<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Configuration<\/td>\n<td valign=\"top\">GUI based Configuration Tool<\/td>\n<\/tr>\n<tr>\n<td valign=\"top\">Supported profiles<\/td>\n<td valign=\"top\">UA 1.02 Embedded Server and Data Access<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p style=\"text-align: center;\"><strong>NOTE<\/strong>:\u00a0 All products are pre-order items<\/p>\n<p style=\"text-align: center;\"><a href=\"https:\/\/www.prosoft-technology.com\/Products\/Gateways\/PLX3x\/PLX32\/EtherNet-IP-to-Modbus-TCP-IP-to-OPC-UA-Server-Gateway\" target=\"_blank\" rel=\"noopener\">Specifications, downloads &amp; certifications<\/a><\/p>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>Need to get data from your EtherNet\/IP\u2122 or Modbus\u00ae TCP\/IP-based devices to your OPC UA clients to be analyzed so you can reduce your operating costs or increase your production?<\/p>\n<p>ProSoft Technology\u2019s EtherNet\/IP to Modbus TCP\/IP to OPC UA Server communication gateway allows high-speed tri-directional data transfers between EtherNet\/IP PACs and Modbus TCP\/IP devices, while also providing an OPC UA Server connection.<\/p>\n<p>The Modbus TCP\/IP driver features multiple, simultaneous client and server connections for faster data transmission. For simplified integration and reduced commissioning time for Rockwell Automation\u00ae EtherNet\/IP-enabled PACs, an EDS AOP is provided.<\/p>\n","protected":false},"featured_media":3230,"comment_status":"open","ping_status":"closed","template":"","meta":[],"product_brand":[],"product_cat":[161,152,158],"product_tag":[560],"class_list":{"0":"post-3228","1":"product","2":"type-product","3":"status-publish","4":"has-post-thumbnail","6":"product_cat-prosoft-ethernet-i-p","7":"product_cat-prosoft-technology","8":"product_cat-industrial-data-communications-gateways","9":"product_tag-data-logger","11":"first","12":"instock","13":"shipping-taxable","14":"product-type-simple"},"_links":{"self":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/3228","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/comments?post=3228"}],"version-history":[{"count":0,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product\/3228\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media\/3230"}],"wp:attachment":[{"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/media?parent=3228"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_brand?post=3228"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_cat?post=3228"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.throughput.co.za\/products\/wp-json\/wp\/v2\/product_tag?post=3228"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}