4 Channel HART Analog Input to Ethernet Gateway

PLX51-HART-4I

The PLX51-HART-4I allows users to easily connect their existing HART-compatible field devices to EtherNet/IP™, Modbus® TCP/IP, and DNP3 Ethernet networks. The module can be used to connect HART Input devices such as process instruments into an Ethernet network. 

The PLX51-HART-4I supports up to 4 channels of HART communication, as well as Analog 4-20 mA signals for real-time process variables to/from the HART-compatible device. 

Description

4 Channel HART Analog Input to Ethernet Gateway

The PLX51-HART-4I allows users to easily connect their existing HART-compatible field devices to EtherNet/IP™, Modbus® TCP/IP, and DNP3 Ethernet networks. The module can be used to connect HART Input devices such as process instruments into an Ethernet network.

The PLX51-HART-4I supports up to 4 channels of HART communication, as well as Analog 4-20 mA signals for real-time process variables to/from the HART-compatible device.

Architectures

schematic PLX51-HART-41

Features and Benefits

  • Support for point-to-multipoint network, maximum of 7 devices (EtherNet/IP only)
  • Support for point-to-point networks with EtherNet/IP, Modbus TCP/IP or DNP3 (TCP/UDP) protocols
  • Support for point to multipoint networks with EtherNet/IP and Modbus TCP/IP protocols
  • Support for automatic configuration in Multidrop mode for Logix Controllers
  • Support for PCCC (AB-ETH) protocol, allowing legacy controllers to easily interface to HART modules
  • Support for Factory Talk View for point to point and multidrop HART devices
  • EtherNet/IP enables a HART device to be added directly into a Rockwell Automation® Logix I/O tree
  • Modbus TCP/IP enables a HART field device to be viewed as a Modbus Slave device
  • DNP3 converts a HART field device into a DNP3 Outstation (slave) supporting Secure Authentication
  • DTM (Device Type Manager) / HART Pass-through is available for simplifying device configuration and management using an FDT frame
  • Built-in webserver provides detailed diagnostics of system configuration and operation as well as field device diagnostics
  • Can be used in a redundant ControlLogix® controller system
  • Advanced Diagnostics automatically extracted and written to Logix Tag

Specifications

HART 4 Channel Input

Specification Description
Number of Channels 4
ADC Resolution 12 bit
Input Impedence 247.5 Ω
Accuracy (Calibrated 25°C) < 0.15 %
Accuracy (Uncalibrated) < 0.30 %
Range 0 to 22 mA
Current limit 34 mA

EtherNet/IP

Specification Description
Connector RJ45
Conductors CAT5 STP/UTP
ARP Connections Max 20
TCP Connections Max 20
CIP Connections Max 10
Communication Rate 10/100 Mbps
Duplex Mode Full / Half
Auto MDIX Yes

Modbus TCP/IP

Specification Description
Function Codes
Supported
1: Read Coils
2: Read Discrete Inputs
3: Read Holding Registers
4: Read Input Registers

DNP3

Specification Description
Mode Supported DNP3 Outstation
Application Functions Supported Read
Write
Select/Operate
Direct-Operate
Direct-Operate-No-Response
Authentication Request
Authentication Response
Unsolicited Response Supported No
DNP3 Events Supported No

DNP3 Secure Authentication

Specification Description
Key Change Method Supported Pre-shared
MAC Algorithms Supported HMAC SHA-1 encryption (4 octets, serial) – for legacy support
HMAC SHA-1 encryption (8 octets, serial)
HMAC SHA-1 encryption (10 octets, networked)
HMAC SHA-256 encryption (8 octets, serial)
HMAC SHA-256 encryption (16 octets, networked)
AES-GMAC (12 octets)
Key Wrap Algorithms Supported AES-128 Key Wrap
AES-256 Key Wrap
Aggressive Mode Supported No

NOTE:  All products are pre-order items