Modbus Serial Lite Communication Module for CompactLogix

MVI69L-MBS

The MVI69L-MBS, Modbus Serial module for the CompactLogix™ series of controllers is designed for smaller applications where communication between a few Modbus Serial devices is required. This module has an Add-on Profile and an Add-on Instruction to reduce commissioning time. The MVI69L-MBS has a single serial port and can support either Master or Slave connectivity to interface with a variety of devices using the Modbus Protocol.

A conformal coating option is available for this product.

Description

Features and Benefits

  • Supports CompactLogix processors with 1769 I/O bus capability version 16 and greater (MicroLogix 1500 not supported)
  • Add-on Instruction creates UDTs, providing logical definitions for I/O, status, and control data
  • Add-on Profile support, improving integration in the CompactLogix System
  • Diagnostic data available in processor controller tags, enabling decisions to be made based upon node health
  • Module configuration backed up in CompactLogix project (ACD file)
  • Module acts as a co-processor reducing impact to PLC scan time
  • Supports up to 240 words of I/O data
  • Application port can be configured as either a Modbus Master or Modbus Slave
  • Supports up to 30 Modbus Commands as a Modbus Master
  • Supports Enron and Daniel style Floating point data implementations
  • Most suitable for OEM and Machine Builder applications

Architectures

MVI69L-MBS schematic

Features and Benefits

  • Supports CompactLogix processors with 1769 I/O bus capability version 16 and greater (MicroLogix 1500 not supported)
  • Add-on Instruction creates UDTs, providing logical definitions for I/O, status, and control data
  • Add-on Profile support, improving integration in the CompactLogix System
  • Diagnostic data available in processor controller tags, enabling decisions to be made based upon node health
  • Module configuration backed up in CompactLogix project (ACD file)
  • Module acts as a co-processor reducing impact to PLC scan time
  • Supports up to 240 words of I/O data
  • Application port can be configured as either a Modbus Master or Modbus Slave
  • Supports up to 30 Modbus Commands as a Modbus Master
  • Supports Enron and Daniel style Floating point data implementations
  • Most suitable for OEM and Machine Builder applications

 

Specifications

Configuration ProSoft Configuration Builder
I/O Size 240/240 – 16 bit integers
Communication
parameters
Baud Rate: 110 to 115K baud
Stop Bits: 1 or 2
Data Size: 7 or 8 bits
Parity: None, Even, Odd
RTS Timing delays: 0 to 65535 milliseconds
Modbus Modes RTU mode (binary) with CRC-16
ASCII mode with LRC error checking
Floating Point
Data
Floating point data movement supported, including configurable support for Enron, Daniel®, and other implementations
Modbus Function
Codes Supported
1: Read Coil Status
2: Read Input Status
3: Read Holding Registers
4: Read Input Registers
5: Force (Write) Single Coil
6: Preset (Write) Single Holding Register
8: Diagnostics (Slave Only, Responds
to Sub function 00)
15: Force (Write) Multiple Coils
16: Preset (Write) Multiple Holding Registers
17: Report Slave ID (Slave Only)
22: Mask Write Holding Register (Slave Only)
23: Read/Write Holding Registers (Slave Only)

NOTE:  All products are pre-order items