DNP 3.0 Master/Slave Communication Module

MVI94-DNP

The MVI94 DNP 3.0 Master/Slave
Communication Module is a single slot, backplane compatible DNP 3.0 interface solution for the Rockwell Automation Flex platform. This module provides highly configurable support of both DNP 3.0 Master and Slave implementations (level 2 minimum), allowing the many SCADA and field devices supporting the DNP protocol to be integrated into the powerful Flex platform.

 

[Limited Availability]

Description

DNP 3.0 Master/Slave Communication Module

The MVI94 DNP 3.0 Master/Slave
Communication Module is a single slot, backplane compatible DNP 3.0 interface solution for the Rockwell Automation Flex platform. This module provides highly configurable support of both DNP 3.0 Master and Slave implementations (level 2 minimum), allowing the many SCADA and field devices supporting the DNP protocol to be integrated into the powerful Flex platform.

Features and Benefits

The module supports DNP Subset Level 2 features and some of the Level 3 features allowing the many SCADA and field devices supporting the DNP protocol to be integrated into the Flex platform. The module acts as an input/output module between the DNP network and the Flex backplane. The data transfer from the Flex processor is asynchronous from the actions on the DNP network. Databases are user defined and stored in the module to hold the data required by the protocol.

The MVI94-DNP module is the ideal solution for many applications where DNP 3.0 master and/or slave protocol connectivity must be added to a FLEX system.

The DNP solution is designed to address the expanding interest in the DNP 3.0 protocol. The protocol was originally developed for the power utility industry and is recommended by the IEEE for RTU-IED communication applications. Additional industrial applications are quickly arising in the water/wastewater and oil & gas industries.

Specifications

Some of the general specifications include:

  • Operation via simple ladder logic
  • Complete setup and monitoring of module through Debug port and user configuration file
  • Flex backplane interface via I/O access

The module has two DNP protocol ports that can be user configured to operate in a Master/Slave or in a Slave/Slave redundant port configuration.

User defined internal register space is accessible to the protocol driver and to the FLEX processor memory.

DNP 3.0 port (PRT2)

  • User-definable module memory usage
  • Full radio, modem and multi-drop support
  • Support for the storage and transfer of all DNP data types across the backplane
  • Communication parameters
    • Address: 0 to 65534 (slave mode)
    • Baud rate: 110 to 115K
    • Parity: none, data bits: 8, Stop bit: 1
    • RTS on delay: 0 to 65535 milliseconds
    • RTS off delay: 0 to 65535 milliseconds

NOTE:  All products are pre-order items