Modbus TCP/IP to Modbus Master/Slave Gateway – 4 Port

PLX31-MBTCP-MBS4

ProSoft Technology’s Modbus® TCP/IP to Modbus® Serial four-port Serial gateway allows high-speed bi-directional data transfers between Modbus® TCP/IP-enabled PACs and Modbus® Serial devices. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors. Four Serial ports allow for connectivity of up to 400 Modbus® Serial devices, reducing the amount of gateways required for your application.

In addition, the gateway includes several features that allow for simplified integration, reduced commissioning time and optimized performance.

A conformal coating option is available for this product.

Description

Modbus TCP/IP to Modbus Master/Slave Gateway – 4 Port

ProSoft Technology’s Modbus® TCP/IP to Modbus® Serial four-port Serial gateway allows high-speed bi-directional data transfers between Modbus® TCP/IP-enabled PACs and Modbus® Serial devices. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors. Four Serial ports allow for connectivity of up to 400 Modbus® Serial devices, reducing the amount of gateways required for your application.

In addition, the gateway includes several features that allow for simplified integration, reduced commissioning time and optimized performance.

A conformal coating option is available for this product.

Architectures

PLX31-MBTCP-MBS4 Schematic

Features and Benefits

  • Gateway includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery.
  • Four Serial ports allow for connectivity of up to 400 Modbus® Serial devices, reducing the amount of gateways required for your application.
  • Supports up to 20 simultaneous client & server connections, allowing for faster communication between devices such as HMIs, SCADA systems, power monitors and flow computers, among others.
  • ProSoft Discovery Service: This utility allows your PC to see the gateway and change its default IP address without being on the same subnet as the module.
  • Secure module configuration via module switch (v1.04 and greater).
  • Up to 10,000 16-bit registers can be used to exchange large amounts of data.

Specifications

Modbus TCP/IP Specifications

Specification Description
Supported Modbus Function Codes 1: Read Coil Status
2: Read Input Status
3: Read Holding Registers
4: Read Input Registers
5: Force (Write) Single Coil
6: Preset (Write) Single Holding Register
15: Force (Write) Multiple Coils
16: Preset (Write) Multiple Holding Registers
22: Mask Write Holding Register (Slave Only)
23: Read/Write Holding Registers (Slave Only)
Supported Clients 10
Supported Servers MBAP: 5
Encapsulated: 5
Command List Up to 160 fully configurable Client commands
Status Data Error codes reported individually for each command
Command List Polling Each command can be individually enabled or disabled;
write-only-on-data-change is available

Modbus Serial Specifications

Specification Description
Command List Up to 100 commands per Master port, each fully configurable for Function Code, slave address, register to/from addressing and word/bit count.
Supported Modbus Function Codes 1: Read Coil Status
2: Read Input Status
3: Read Holding Registers
4: Read Input Registers
5: Force (Write) Single Coil
6: Preset (Write) Single
Holding Register
15: Force (Write) Multiple Coils
16: Preset (Write) Multiple Holding Registers
22: Mask Write Holding Register (Slave Only)
23: Read/Write Holding Registers (Slave Only)
Software configurable communication parameters Baud rate: 110 baud to 115.2 kbps
Parity: None, Even, Odd
Data Size: 7 or 8 bits
Stop bits: 1 or 2
RTS on/off delay: 0 to 65535 milliseconds
Modbus RTU mode (binary) with CRC-16
Modbus ASCII mode with LRC error checking
Floating Point Data Floating point data movement supported, including configurable support for Enron and Daniel implementations
Polling of Command List Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.
Status Data Error codes available on an individual command basis. In addition, a slave status list is maintained
Node Address 1 to 247 (software selectable)
RS Interface RS232, RS422, and RS485
Transmit and Receive Buffer Size 255 byte Transmit character length with 0 to 65535 millisecond delay between each transmitted character

NOTE:  All products are pre-order items