Modbus TCP/IP to Modbus Serial Communication Module
PLX31-MBTCP-MBS
ProSoft Technology’s Modbus® TCP/IP to Modbus® Serial communication gateway allows high-speed bi-directional data transfers between Modbus® TCP/IP-enabled PACs and Modbus® Serial devices. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors.
In addition, the gateway has several features that allow simplified integration, reduced commissioning time and optimized performance.
A conformal coating option is available for this product.
- Description
Description
Modbus TCP/IP to Modbus Serial Communication Module
ProSoft Technology’s Modbus® TCP/IP to Modbus® Serial communication gateway allows high-speed bi-directional data transfers between Modbus® TCP/IP-enabled PACs and Modbus® Serial devices. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors.
In addition, the gateway has several features that allow simplified integration, reduced commissioning time and optimized performance.
A conformal coating option is available for this product.
Architectures
Specifications
Modbus® TCP/IP Specifications
Specification | Description | |
Supported Modbus Function Codes | 1: Read Coil Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil 6: Preset (Write) Single Holding Register |
15: Force (Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers 22: Mask Write Holding Register (Slave Only) 23: Read/Write Holding Registers (Slave Only) |
Supported Clients | 10 | |
Supported Servers | MBAP: 5 Encapsulated: 5 |
|
Command List | Up to 160 fully configurable Client commands | |
Status Data | Error codes reported individually for each command | |
Command List Polling | Each command can be individually enabled or disabled; write-only-on-data-change is available |
Modbus Serial Specifications
Specification | Description | |
Command List | Up to 100 commands per Master port, each fully configurable for Function Code, slave address, register to/from addressing and word/bit count. | |
Supported Modbus Function Codes | 1: Read Coil Status 2: Read Input Status 3: Read Holding Registers 4: Read Input Registers 5: Force (Write) Single Coil 6: Preset (Write) Single Holding Register |
15: Force (Write) Multiple Coils 16: Preset (Write) Multiple Holding Registers 22: Mask Write Holding Register (Slave Only) 23: Read/Write Holding Registers (Slave Only) |
Software configurable communication parameters | Baud rate: 110 baud to 115.2 kbps Parity: None, Even, Odd Data Size: 7 or 8 bits Stop bits: 1 or 2 RTS on/off delay: 0 to 65535 milliseconds Modbus RTU mode (binary) with CRC-16 Modbus ASCII mode with LRC error checking Floating Point Data Floating point data movement supported, including configurable support for Enron and Daniel implementations |
|
Polling of Command List | Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled. | |
Status Data | Error codes available on an individual command basis. In addition, a slave status list is maintained | |
Node Address | 1 to 247 (software selectable) | |
RS Interface | RS232, RS422, and RS485 | |
Transmit and Receive Buffer Size | 255 byte Transmit character length with 0 to 65535 millisecond delay between each transmitted character |