Rockwell Automation In-Chassis
-
3170-MBS
The MVI94 Modbus Slave Network Interface Adapter can interface up to 8 Rockwell Automation FLEX and/or Integra I/O modules directly with any Modbus Master.
-
3170-PDP
The 3170-PDP PROFIBUS-DP Network Interface Adapter is a slave device that allows Rockwell Automation FLEX and/or Integra I/O modules to interface directly with a PROFIBUS-DP Master/Scanner.
-
CLX-422-IPC
The Honeywell IPC module allows an Allen-Bradley ControlLogix Processor to control a Honeywell IPC 620 I/O devices. This module allows a phased migration approach to be used when upgrading or replacing Honeywell’s SLM 621-9939 Scanners. This In-chassis module provides automatic detection of the IPC I/O racks and modules. After the direction of the I/O cards has been entered the associated RSLogix 5000 tags can be auto generated significantly reducing engineering effort.
-
CLX-APACS
The CLX-APACS module enables a ControlLogix / Plant-PAx™ system to control Moore/Siemens APACS+ IO Bus remote I/O racks. This provides the ability to execute a phased migration of old Moore APACS DCS systems.
-
CLX-PVX
The Fisher PROVOX® module allows an Allen-Bradley® ControlLogix® processor to control PROVOX I/O devices. This module allows a phased migration approach to be used when upgrading or replacing the PROVOX controllers. The gateway provides automatic creation of the PROVOX network scan-list and generates the associated RSLogix™ 5000 tags reducing engineering effort.
-
ILX34-MBS232
ProSoft Technology’s ILX34-MBS232 module is ideal for point to point applications with a maximum distance of 50 feet away (15.2 meters) your processor. These include SCADA and field device interface applications. The module can be used in CompactLogix L1 processors or Distributed 1734 Point I/O systems. In addition, the module can be configured as a Master or Slave.
-
ILX34-MBS485
ProSoft Technology’s ILX34-MBS485 module is ideal to connect multiple devices up to 4,000 feet (1,219 meters) from your processor. These include SCADA and field device interface applications. The module can be used in CompactLogix L1 processors or Distributed 1734 Point I/O systems. In addition, the module can be configured as a Master or Slave.
-
ILX56-PBM
The ILX56-PBM PROFIBUS DPV1 Master/Multi-Slave module allows Rockwell Automation® ControlLogix® processors to communicate with various PLCs and devices using the PROFIBUS DP protocol. As a PROFIBUS DP Master, the module can transfer up to 5000 bytes of cyclic I/O data with various slave devices on the network.
Or you can use the module as a PROFIBUS DP multi-slave, where the module can emulate up to 10 individual nodes on a PROFIBUS DP network, allowing for more cyclic I/O data transfer.
-
ILX69-PBM
The ILX69-PBM PROFIBUS DPV1 Master module provides all the advantages of in-chassis PROFIBUS communication, such as the inclusion of an AOI and the Autoscan features which greatly reduce your commissioning time, and ComDTM that provides remote Ethernet connectivity with asset management software.
With these modules, CompactLogix™ processors can easily communicate with slave devices supporting PROFIBUS DPV0 and DPV1 protocol. The module acts as an input/output module between the PROFIBUS network and the processor supporting complete Master specifications according to IEC 61158.
-
ILX69-PBS
The ILX69 PROFIBUS Slave module is an in-chassis PROFIBUS DPV1 Slave for CompactLogix, supporting cyclic PROFIBUS I/O data and acyclic messaging.
Explicit ladder logic CIP message blocks provide slave status diagnostic data and the ability for acyclic messaging.The ILX69 interface appears to the CompactLogix controller as a standard I/O module allowing it to be configured via Studio/RSLogix™5000. The cyclic PROFIBUS I/O data can be configured in Studio/RSLogix™ 5000, or configuration can be transferred from the Master to the slave module.
-
MVI46-104S
The MVI46 IEC 60870-5-104 Server Network Interface Module allows SLC processors to interface easily with IEC 60870-5-104 protocol-compatible hosts. The MVI46-104S module has been designed to address applications where a device using the IEC 60870-5-104 protocol needs to communicate with a SLC processor. Functionality of the IEC protocol is very similar to the DNP 3.0 protocol which features time stamping and True Report by Exception (TRBE).