Specisalised Ethernet Protocol

  • You've just added this product to the cart:

    ILX56-MM

    ILX56-MM
    ILX56-MM

    ILX56-MM

    The ProSoft Technology inRAx Message Manager is a single-slot solution that connects and transfers Factory and Plant Process Automation monitoring and control data between islands of automation across diverse platforms, networks and protocols.

    The inRAx Message Manager is an easy-to-use data transfer engine for the ControlLogix 1756 platform, supporting Rockwell Automation Programmable Logic Controller (PLC) and Programmable Automation Controller (PAC) network protocols, as well as platforms and devices that use Siemens Industrial Ethernet and Modbus TCP/IP protocols.

  • You've just added this product to the cart:

    MVI46-104S

    MVI46-104S-Ethernet
    MVI46-104S-Ethernet

    MVI46-104S

    The MVI46 IEC 60870-5-104 Server Network Interface Module allows SLC processors to interface easily with IEC 60870-5-104 protocol-compatible hosts. The MVI46-104S module has been designed to address applications where a device using the IEC 60870-5-104 protocol needs to communicate with a SLC processor. Functionality of the IEC protocol is very similar to the DNP 3.0 protocol which features time stamping and True Report by Exception (TRBE).

  • You've just added this product to the cart:

    MVI46-DNPSNET

    MVI46-DNPSNET ethernet
    MVI46-DNPSNET ethernet

    MVI46-DNPSNET

    The DNP 3.0 Ethernet Server Network Interface Module allows SLC processors to interface with the many field devices that support the DNP protocol over Ethernet. DNP (Distributed Network Protocol) is an open communication protocol developed to achieve interoperability among systems specifically in the electric utility, oil & gas and water/wastewater industries.

  • You've just added this product to the cart:

    MVI56-DNPSNET

    MVI56-Ethernet
    MVI56-Ethernet

    MVI56-DNPSNET

    The DNP 3.0 Ethernet Server Network Interface Module allows ControlLogix processors to interface with the many field devices that support the DNP protocol over Ethernet. DNP (Distributed Network Protocol) is an open communication protocol developed to achieve interoperability among systems specifically in the electric utility, oil & gas and water/wastewater industries.

  • You've just added this product to the cart:

    MVI56-EGD

    MVI56-EGD
    MVI56-EGD

    MVI56-EGD

    The Ethernet Global Data (EGD) module can be used to interface many different protocols with EGD devices. The EGD driver supports both the producer/consumer service port (18246) and the command service port (7937) using the UDP protocol over an IP network. The user defines the data to be produced and consumed in a configuration file downloaded to the module.

  • You've just added this product to the cart:

    MVI56-SMGC

    MVI56-Serial
    MVI56-Serial

    MVI56-SMGC

    The MVI56-SMGC module interfaces an Ethernet communication device using the SM General Communication Protocol with the ControlLogix processor. A single client is present in the module to interface with a single server. The client permits both the reception and transmission of data between the ControlLogix processor and attached device.

  • You've just added this product to the cart:

    MVI56E-DNPNET

    MVI56E-DNPNET
    MVI56E-DNPNET

    MVI56E-DNPNET

    The MVI56E DNP3 Ethernet Communication Module allows Rockwell Automation ControlLogix ® PACs to interface on a DNP3 Ethernet network. The module supports operation as an Ethernet Client with up to 40 DNP3 Ethernet server devices such as RTU’s, IED’s, and various protection relays. With support for 300 user definable commands and a maximum of up to 20,000 points of data, the module can be used to obtain data from a network of devices over a DNP3 Ethernet link.

  • You've just added this product to the cart:

    MVI56E-FLN

    MVI56E-FLN
    MVI56E-FLN

    MVI56E-FLN

    The MVI56E-FLN FA Control Network Enhanced communication module is a single-slot solution that allows ControlLogix-compatible processors to easily interface with other FL-net protocol devices. The module is certified for use with FL-net version 2.00 (OPCN-2) for the standard FA control network, as defined by JEMA (The Japan Electrical Manufacturers Association).

  • You've just added this product to the cart:

    MVI56E-SIE

    MVI56E-SIE
    MVI56E-SIE

    MVI56E-SIE

    The MVI56E Siemens Industrial Ethernet Communication Module allows Rockwell Automation ControlLogix Programmable Automation Controllers (PACs) to interface easily as an Ethernet Client with up to a maximum of 20 Siemens S7-200, S7-1200, S7-300, and S7-400 PLCs operating as Ethernet servers.

    The module uses ProSoft Configuration Builder (PCB) which provides a graphical configuration tool for management of module configuration files, as well as viewing communication and module diagnostic information using the high-speed Ethernet port.

  • You've just added this product to the cart:

    MVI69-104S

    MVI69-FLN-ethernet
    MVI69-FLN-ethernet

    MVI69-104S

    The MVI69 IEC 60870-5-104 Edition 2 Ethernet Server Communication Module allows Rockwell Automation CompactLogix processors to interface easily with IEC 60870-5-104 protocol hosts. This latest version of ProSoft Technology’s IEC-104 server solution has been enhanced with additional IEC-104 Edition 2 data types and Causes for Transmission. These enhancements extend the capability and applicability of an already powerful solution. The new version also offers increased Event Buffer management options.

  • You've just added this product to the cart:

    MVI69-DNPSNET

    MVI69-FLN-ethernet
    MVI69-FLN-ethernet

    MVI69-DNPSNET

    The MVI69 DNP 3.0 Server Ethernet Communications Module supports the implementation of the DNP 3.0 (Distributed Network Protocol) over Ethernet, allowing CompactLogix processors to easily communicate with host systems supporting the protocol. The module supports DNP Subset Level 2 features and some Level 3 features.

  • You've just added this product to the cart:

    MVI69-EGD

    MVI69-FLN-ethernet
    MVI69-FLN-ethernet

    MVI69-EGD

    The MVI69-EGD Ethernet Global Data (EGD) module can be used to interface many different protocols with EGD devices. The EGD driver supports both the producer/consumer service port (18246) and the command service port (7937) using the UDP protocol over an IP network. The user defines the data to be produced and consumed in a configuration file downloaded to the module.