EtherNet/IP to Siemens Industrial Ethernet Communication Gateway
PLX32-EIP-SIE
ProSoft Technology’s EtherNet/IP™ to Siemens® Industrial Ethernet communication gateway allows high-speed bi-directional data transfers between Rockwell Automation® PACs and Siemens® S7 PACs. Two separate Ethernet ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address.
In addition, the gateway includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.
- Description
Description
EtherNet/IP to Siemens Industrial Ethernet Communication Gateway
ProSoft Technology’s EtherNet/IP™ to Siemens® Industrial Ethernet communication gateway allows high-speed bi-directional data transfers between Rockwell Automation® PACs and Siemens® S7 PACs. Two separate Ethernet ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address.
In addition, the gateway includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.
Architectures
Features and Benefits
- Two separate Ethernet ports allow each protocol to reside on separate subnets. This allows you to pass data between the two subnets without changing each device’s IP address to be on the same subnet.
- Data prioritization: Multiple I/O connections allow you to set RPIs for status and/or control data.
- Includes an embedded EDS Add-On Profile, allowing for simplified integration and reduced commissioning time.
- Gateway includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery.
- Secure module configuration via module switch (v1.04 and greater).
- Up to 10,000 16-bit registers can be used to exchange large amounts of data
Specifications
EtherNet/IP™ Specifications
Specification | Description |
Number of Class 3 Server Connections | 5 |
Supported PLC Types | PLC2, PLC5, SLC, CLX, CMPLX, MICROLX |
Supported Message Types | PCCC and CIP |
Class 3 Client Connections | Connected: 2 Unconnected: 1 |
Number of Class 1 I/O Connections | 2 |
I/O connection sizes | 248/248 |
Max RPI time | 5 ms per connection |
CIP Services Supported | 0x4C – CIP Data Table Read 0x4D – CIP Data Table Write |
Command List | Support for 100 commands per Client, each configurable for command type, IP address, register to/from addressing and word/bit count. |
Command Sets | PLC-2/PLC-3/PLC5 Basic Command Set PLC5 Binary Command Set PLC5 ASCII Command Set SLC500 Command Set |
Siemens® Industrial Ethernet Specifications
Specification | Description |
Supported PLC Data Exchange (Read and Write) | Siemens S7-200, S7-300, S7-400, S7-1200, S7-1500 |
Supported Register Types | DB, Inputs, Outputs, Flags, Counters, Timers |
Supported Clients | 20 |