Modbus TCP/IP to Siemens Industrial Ethernet Communication Gateway

PLX32-MBTCP-SIE

ProSoft Technology’s Modbus® TCP/IP to Siemens Industrial Ethernet gateway allows high speed bi-directional data transfers between Schneider Electric® PACs and Siemens S7 and S5 PACs.

Two ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address. 

Description

Modbus TCP/IP to Siemens Industrial Ethernet Communication Gateway

ProSoft Technology’s Modbus® TCP/IP to Siemens Industrial Ethernet gateway allows high speed bi-directional data transfers between Schneider Electric® PACs and Siemens S7 and S5 PACs.

Two ports allow each protocol to reside on separate subnets, allowing you to pass data between the two subnets without changing each device’s IP address.

Architectures

PLX32-MBTCP-SIE Schematic

Features and Benefits

  • Two separate Ethernet ports allow each protocol to reside on separate subnets. This allows you to pass data between the two subnets without changing each device’s IP address to be on the same subnet.
  • In addition to S7 controllers, the gateway can also be used with Siemens S5 controllers with an appropriate interface.
  • Gateway includes a SD card slot (SD card optional) for storing configuration files. This can be used for disaster recovery.
  • Secure module configuration via module switch (v1.04 and greater).
  • Up to 10,000 16-bit registers can be used to exchange large amounts of data

Specifications

Modbus TCP/IP Specifications

Specification Description
Supported Modbus Function Codes 1: Read Coil Status
2: Read Input Status
3: Read Holding Registers
4: Read Input Registers
5: Force (Write) Single Coil
6: Preset (Write) Single Holding Register
15: Force (Write) Multiple Coils
16: Preset (Write) Multiple Holding Registers
22: Mask Write Holding Register (Slave Only)
23: Read/Write Holding Registers (Slave Only)
Supported Clients 10
Supported Servers MBAP: 5
Encapsulated: 5
Command List Up to 160 fully configurable Client commands
Status Data Error codes reported individually for each command
Command List Polling Each command can be individually enabled or disabled;
write-only-on-data-change is available

Siemens Industrial Ethernet Specifications

Specification Description
Supported PLC Data Exchange (Read and Write) Siemens S7-200, S7-300, S7-400, S7-1200, S7-1500
Supported Register Types DB, Inputs, Outputs, Flags, Counters, Timers
Supported Clients 20

NOTE:  All products are pre-order items